摘要 AIM: To design and establish a method of multiplex PCR normalization for simultaneously detecting HBV and HCV.METHODS: Two pairs of primers with a 20 bp joint sequence were used to amplify the target genes of HBV and HCV by two rounds of amplification. After the two rounds of amplification all the products had the joint sequence. Then the joint sequence was used as primers to finish the last amplification. Finally multiplex PCR was normalized to a single PCR system to eliminate multiplex factor interference. Four kinds of nucleic acid extraction methods were compared and screened. A multiplex PCR normalization method was established and optimized by orthogonal design of 6 key factors. Then twenty serum samples were detected to evaluate the validity and authenticity of this method.RESULTS: The sensitivity, specificity, diagnostic index and efficiency were 83.3%, 70%, 153.3% and 72.2%,respectively for both HBsAg and anti-HCV positive patients,and were 78.6%, 80%, 258.6% and 79.2%, respectively for HBsAg positive patients, and were 75%, 90%, 165% and 83.3%, respectively for anti-HCV positive patients.CONCLUSION: The multiplex PCR normalization method shows a broad prospect in simultaneous amplification of multiple genes of different sources. It is practical, correct and authentic, and can be used to prevent and control HBV and HCV. AIM:To design and establish a method of multiplex PCR normalization for simultaneously detecting HBV and HCV. METHODS:Two pairs of primers with a 20 bp joint sequence were used to amplify the target genes of HBV and HCV by two rounds of amplification.After the two rounds of amplification all the products had the joint sequence.Then the joint sequence was used as primers to finish the last amplification.Finally multiplex PCR was normalized to a single PCR system to eliminate multiplex factor interference.Four kinds of nucleic acid extraction methods were compared and screened.A multiplex PCR normalization method was established and optimized by orthogonal design of 6 key factors.Then twenty serum samples were detected to evaluate the validity and authenticity of this method. RESULTS:The sensitivity,specificity,diagnostic index and efficiency were 83.3%,70%,153.3% and 72.2%, respectively for both HBsAg and anti-HCV positive patients, and were 78.6%,80%,258.6% and 79.2%,respectively for HBsAg positive patients,and were 75%,90%,165% and 83.3%,respectively for anti-HCV positive patients. CONCLUSION:The multiplex PCR normalization method shows a broad prospect in simultaneous amplification of multiple genes of different sources.It is practical,correct and authentic,and can be used to prevent and control HBV and HCV.
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2004年第16期2439-2443,共5页 世界胃肠病学杂志(英文版)
基金 Supported by the National Key Technology Research and Development Program of China during the 9th Five-Year Plan Period, No.96C020117
  • 相关文献

参考文献16

  • 1Hu KQ, Yu CH, Lee S, Villamil FG, Vierling JM. Simultaneous detection of both hepatitis B virus DNA and hepatitis C virus RNA using a combined one-step polymerase chain reaction technique. Hepatology 1995; 21:901-907.
  • 2Yamada O, Matsumoto T, Nakashima M, Hagari S, Kamahora T, Ueyama H, Kishi Y, Uemura H, Kurimura T. A new method for extracting DNA or RNA for polymerase chain reaction. J Virol Methods 1990; 27:203-209.
  • 3Boom R, Sol CJ, Salimans MM, Jansen CL, Wertheim-van Dillen PM, van der Noordaa J. Rapid and simple method for purification of nucleic acids. J Clin Microbiol 1990; 28:495-503.
  • 4Vogelstein B, Gillespie D. Preparative and analytical purification of DNA from agarose. Proc Natl Acad Sci U S A 1979; 76:615-619.
  • 5Han JX, Zhang C, Yang XC, Tang TH, Wang ML. Investigation on the purification and synthesizing of DNA fragments by OPC methods. Shandong, Yike Daxue Xuebao 1995; 33:173-174.
  • 6Fang JQ, Fu CZ, Liao I~R. Regression methods of pair -wise data. Zhongguo Weisheng Tongji 1996; 13:1-5.
  • 7Xu ZF, Xu KC, Meng XY. Investigation on the double infection of HBV and HCV. Nantong, Yixueyuan Xuebao 1994; 14:162-165.
  • 8Konomi N, Yamaguchi M, Naito H, Aiba N, Saito T, Arakawa Y, Abe K. Simultaneous detection of hepatitis B, C, and G viral genomes by multiplex PCR method. Jpn J Infect Dis 2000; 53:70 -72.
  • 9Meng Q, Wong C, Rangachari A, Tamatsukuri S, Sasaki M,Fiss E, Cheng L, Ramankutty T, Clarke D, Yawata H, Sakakura Y, Hirose T, Impraim C. Automated multiplex assay system for simultaneous detection of hepatitis B virus DNA, hepatitis C virus RNA, and human immunodeficiency virus type 1 RNA.J Clin Microbiol 2001: 39:2937-2945.
  • 10Wang YF, Pang DW, Zhang ZL, Zheng HZ, Cao JP, Shen JT.Visual gene diagnosis of HBV and HCV based on nanoparticle probe amplification and silver staining enhancement. J Med Virol 2003; 70:205-211.

同被引文献1

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部