摘要 通过对衡丰发电有限责任公司1号机组引风机实际运行工况分析,提出引风机节能改造的必要性;介绍改造方案、实施情况及运行效果。通过改造,提高了风机效率,降低了风机电耗,达到了节能降耗的目的。 Through analyzing the actual operation condition of induced draft fans of No. 1 generating unit in Hebei Hengfeng Power Genera-tion Company Ltd., the necessity of energy-saving retrofit of induced draft fans was brought forward. This paper briefed the retrofittingscheme, implementation situation and operation effect. Through the retrofit, the efficiency of induced draft fans was raised and the electricityconsumption of induced draft fans was reduced, with the target of energy-saving and consumption-reducing achieved.
出处 《中国电力》 CSCD 北大核心 2004年第9期70-72,共3页 Electric Power
关键词 锅炉 引风机 节能 技术改造 300MW机组 induced draft fan energy-saving retrofit
  • 相关文献

参考文献2

  • 1宋汉武.火力发电设备技术手册(第四卷火电站系统与辅机)[M].北京:机械工业出版社,2001..
  • 2.AN系列静叶可调轴流通风机产品使用说明书[Z].成都电力机械厂,1995..