摘要
通过对衡丰发电有限责任公司1号机组引风机实际运行工况分析,提出引风机节能改造的必要性;介绍改造方案、实施情况及运行效果。通过改造,提高了风机效率,降低了风机电耗,达到了节能降耗的目的。
Through analyzing the actual operation condition of induced draft fans of No. 1 generating unit in Hebei Hengfeng Power Genera-tion Company Ltd., the necessity of energy-saving retrofit of induced draft fans was brought forward. This paper briefed the retrofittingscheme, implementation situation and operation effect. Through the retrofit, the efficiency of induced draft fans was raised and the electricityconsumption of induced draft fans was reduced, with the target of energy-saving and consumption-reducing achieved.
出处
《中国电力》
CSCD
北大核心
2004年第9期70-72,共3页
Electric Power