摘要
分析荆门热电厂3号锅炉的受热面回转式空气预热器漏风率大的原因,综合比较各种改进方案后提出改进措施。改造后漏风率降低到12%以下,经济效益及投资收益显著。
The cause of large air leakage rate of rotary air preheater of No.3 boiler in Jingmen Cogeneration Power plant Was analyzed andthe improvement measures were put forward after the various improvement schemes were comprehensively compared. After retrofitting, theair leakage rate has been dropped to below 12%, with significant economic benefit and investment benefit obtained.
出处
《中国电力》
CSCD
北大核心
2004年第9期73-76,共4页
Electric Power