期刊文献+

脉冲等离子体烟气脱硫反应器电极配置对能量利用的影响 被引量:5

Influence of the Electrode Configuration of a Pulse Plasma-based Flue Gas Desulfurization Reactor on Energy Utilization
下载PDF
导出
摘要 实验研究了线-板式脉冲电晕放电烟气脱硫反应器的电极结构配置对脉冲能量利用的影响。结果表明在一定实验条件下增加电晕线数、减小线板间距能提高反应器对脉冲能量的利用;在电场长度一定下,线线间距为线板间距的0.6~1倍时,反应器对脉冲能量的利用达到最大。 The influence of the electrode configuration of a wire-plate pulse corona discharge-based desulfurization reactor on pulsed energy utilization is investigated by tests. Test results indicate that under certain test conditions an increase in corona discharge wires and a decrease in wire-plate spacing can enhance the utilization of pulsed energy by the reactor. At a given electric field intensity when the wire-wire spacing is 0.6 - 1 times that of the wire-plate, the utilization of pulsed energy by the reactor will reach a maximum value.
出处 《热能动力工程》 CAS CSCD 北大核心 2004年第5期458-461,共4页 Journal of Engineering for Thermal Energy and Power
基金 国家高技术研究发展计划(863)专项基金资助项目(2001AA642010)
关键词 脉冲等离子体 烟气脱硫 反应器 电极配置 脉冲能量 pulse plasma, flue gas desulfurization, reactor, electrode configuration, pulsed energy
  • 相关文献

参考文献7

  • 1MASUDA S. Pulse corona induced plasma chemical process: a horizon of new plasma chemical technologies[J]. Pure & Appl Chem,1988, 60(5):727-731.
  • 2DINELLI G, CIVITANO L, REA M. Industial experiments on pulse simultaneous removal of NOx and SOx from flue gas[J]. IEEE Trans Ind Appl, 1990,26(3):535-541.
  • 3HSIAO M C, MERRITT B T, PENETRANTE B M,et al. Plasma-assisted decomposition of methanol and trichloroethylene in atmospheric pressure air streams by electrical discharge processing[J]. J Appl Phys,1995,78(5): 3451-3456.
  • 4LI JIE, WU YAN, WANG NING HUI. Industrial-scale experiments of desulfuration of coal flue gas using a pulsed corona discharge plasma[J]. IEEE Transactions on Plasma Science, 2003,31(3):333-337.
  • 5WU YAN, LI JIE, WANG NING HUI. Industrial experiments on desulfurization of flue gases by pulsed corona induced plasma chemical process[J]. Journal of Electrostics, 2003, 57:233-241.
  • 6LEE YONG HWAN, JUNG WONG SUK. Application of pulsed corona induced plasma chemical process to an industrial incinerator[J].Environ Sci Technol,2003,37(11):2563-2567.
  • 7张彦彬,王宁会,吴彦.3000 m^3/h 烟气脱硫试验系统的设计与运行[J].大连理工大学学报,1997,37(5):551-554. 被引量:16