期刊文献+

中心回燃式燃油锅炉燃烧室实验研究 被引量:3

Experiments of Oil -fired Boiler Chamber with Central Reverse Flame
下载PDF
导出
摘要 中心回燃式锅炉自引进以来一直没有一种理想的燃烧室传热计算方法 ,本文根据中心回燃式锅炉燃烧室内射流火焰与回流烟气之间存在着强烈的掺混 ,认为燃烧室传热计算中不应忽略对流换热。提出了适合中心回燃式锅炉燃烧室传热的计算方法 ,并通过实验加以验证。 An ideal heat transfer calculation method has not been found since central reverse flame oil (gas)-fired boiler was introduced.There is a strong adulteration between the jet and the circumfluence occurs in combustion.Thus both radiation and convection need to be considered for the heat transfer flux calculation in the chamber.According to the above theory,a new heat transfer calculation method suitable for central reverse flame oil(gas)-fired boiler was brought forward and verified by experiments.
作者 孙静涛 张龙
出处 《节能技术》 CAS 2004年第5期33-34,58,共3页 Energy Conservation Technology
关键词 中心回燃 燃油锅炉 燃烧室 传热计算 central flame flame oil transfer calculation
  • 相关文献

参考文献4

二级参考文献18

  • 1刘桢干,史丕贤.内燃锅壳式燃油锅炉炉膛出口烟温计算公式中系数“M”的确定[J].工业锅炉,1994(2):17-19. 被引量:1
  • 2谷企平.燃油锅炉的几个实际问题及探析[J].工业锅炉,1996(1):11-12. 被引量:3
  • 3哈尔滨工业大学.燃油锅炉设计和运行[M].国防科技出版社,1985..
  • 4燃油、燃气锅炉房设计手册编写组.燃油、燃气锅炉房设计手册[M].北京:机械工业出版社,1998..
  • 5中小型燃气锅炉房设计手册编写组.中小型燃气锅炉房设计手册[M].北京:中国建筑工业出版社,1981..
  • 6陈立勋,锅炉本体布置及计算,1990年
  • 7哈尔滨工业大学,燃油锅炉设计和运行,1985年
  • 8北京锅炉厂设计科译。锅炉机组热力计算标准方法[M].北京:机械工业出版社,1973
  • 9张忠铭编著。单头螺纹管在工业锅炉中的应用[M].北京:机械工业出版社,1990
  • 10GB16508-1996,锅壳锅炉受压元件强度计算[S].国家技术监督局

共引文献15

同被引文献16

引证文献3

二级引证文献1