摘要 A new flow injection electrogenerated chemiluminescence(ECL)method for the determination of pefloxacin was developed.The method is based on the sensitiving effect of pefloxacin on the weak ECL signal of electrochemical oxidation of luminol on the platinum flake electrode in the medium of 0.05mol/L Na2CO3-NaHCO3.This ECL response is in the range of 1.0×10-8~1.4×10-5g/ml pefloxacin with a detection limit of 8.0×10-9g/ml.The relative standard deviation is 2.5%.This method was used to determine pefloxacin in samples with satisfactory results. A new flow injection electrogenerated chemiluminescence(ECL)method for the determination of pefloxacin was developed.The method is based on the sensitiving effect of pefloxacin on the weak ECL signal of electrochemical oxidation of luminol on the platinum flake electrode in the medium of 0.05mol/L Na_2CO_3-NaHCO_3.This ECL response is in the range of 1.0×10^(-8)~1.4×10^(-5)g/ml pefloxacin with a detection limit of 8.0×10^(-9)g/ml.The relative standard deviation is 2.5%.This method was used to determine pefloxacin in samples with satisfactory results.
出处 《化学研究与应用》 CAS CSCD 北大核心 2004年第5期713-714,716,共3页 Chemical Research and Application
基金 国家自然科学基金(397301610) 陕西省教育厅科研基金资助课题(04JK305)
关键词 电化学发光分析 甲磺酸培氟沙星 鲁米诺 流动注射分析 Electrogenerate chemiluminescence pefloxacin flow injection analysis luminol