摘要 为了解决普通脚手钢管扣件竖井架在大型冷却塔工程施工中的运用,分析研究并选择了比较经济合理、安全可靠的结构组合形式来独立完成120m超高井架的施工.由于普通脚手钢管扣件式脚手架犤1犦在以往的施工中,一般高度都在100m以下,且管壁较薄,直径小,因此,该技术关键是按初步选定的竖井架断面和缆风绳直径,通过分析各杆件及组合断面的力学特性,计算出竖井架的截面惯性矩、抗弯刚度、回转半径及格构折减系数,来校核竖井架杆身正应力、局部稳定性、整体稳定性和自振周期,从而保证普通脚手钢管扣件竖井架在大型冷却塔工程施工中的安全性. In order to apply ordinary steel pipe bucklized scaffold on large sized cooling tower construction, the paper analyses and studies on how to choose comparatively economic, rational and safe structures to independantly accomplish the 120 m super high shaft construction. The ordinary steel pipe bucklized scaffold in past constructions is normally within 100 m high with thin pipe wall and small diameter. Therefore, the key of this technique is to calibrate the section and diameter of shaft, partial stability, intergral stability and self vibration period by studying the mechanical properties of components and composit sections, and by analysing the inertia of boundary surface, bending strength, radius of gyration and lattice coefficient to guarantee the security of the ordinary scaffolding steel pipe bucklized shaft.
出处 《宁夏工程技术》 CAS 2003年第4期307-309,共3页 Ningxia Engineering Technology
关键词 普通脚手钢管 架设 高度高 安全可靠 计算重点 ordinary steel pipe scaffold set up height safety calculation stress
  • 相关文献

参考文献2

  • 1中华人民共和国建设部.JGJ130-2001建筑施工扣件式脚手架安全技术规范[S].北京:中国建筑出版社,2001.
  • 2中华人民共和国电力部.SDJ69-87电力建筑施工及验收技术规范(建筑工程篇)[S].北京:中国电力出版社,1987.

同被引文献2

  • 1中华人民共和国建设部.JGJ 130-2001 建筑施工扣件式钢管脚手架安全技术规范 [S].北京:中国建筑工业出版社,2001.
  • 2龙奴球,包世华.结构力学教程:上册 [M].北京:高等教育出版社,1988.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部