期刊文献+

氧速率法测定血清葡萄糖与其他方法的比较 被引量:1

Comparison of the Glucose Oxidase-Oxygen Rate Method with the Other Methods in Determining Blood Sugar
下载PDF
导出
摘要 为了评价GOD-OR法的性能,笔者采用了GOD-OR法、HK法和GOD法对血清葡萄糖进 行测定比较.结果表明:GOD-OR法的精密度、准确度以及与HK法、GOD法的相关性均较好,其抗 干扰性能均优于后两法. To evaluate the method of glucose oxidase-oxygen rate, a comparison was made between the glucose oxygen rate (GOD-OR) method and the hexokinase (HK) method, the glucose oxidase (GOD) method by determining blood sugar. It showed that GOD-OR method is better than those of HK and GOD in precision and accuracy, and the results by GOD-OR method have a good correlation with those by HK and GOD, also the former is superior to the HK method and GOD method in anti-interference.
作者 邱辅佑 马明
出处 《海南大学学报(自然科学版)》 CAS 2004年第3期266-269,共4页 Natural Science Journal of Hainan University
关键词 氧速率法 测定 血清葡萄糖 GOD-OR法 glucose oxidase-oxygen rate method blood sugar determination
  • 相关文献

参考文献1

  • 1林其燧 文庆成.临床生化诊断大全[M].北京:北京大学出版社,1990.90-91.

同被引文献11

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部