期刊文献+

用开管法快速测定废水的COD 被引量:17

Rapid Determination of COD in Wastewater by Opening-tube Method
下载PDF
导出
摘要 介绍了用硫酸锰代替硫酸银作催化剂快速开管测定废水COD的方法 ,最佳测定条件为 :消解温度 170℃ ,消解时间 12min ,酸度 11mol/L ,催化剂 (硫酸锰 )用量 10 g/L。该方法使试样的消解时间由标准法的 2h缩短到 12min ,同时用硫酸锰代替价格昂贵的硫酸银可大大降低分析成本 ,而准确度和精密度与用硫酸银作催化剂的开管法基本相同 ,COD测定下限为6 5mg/L。该方法可同时消解多个试样 ,适用于大批量水样的测定。 Rapid determination of COD in wastewater using opening-tube method and MnSO_4 as catalyst instead of Ag_2SO_4 is described.The optimum determining conditions are as follows:decomposition temperature 170 ℃,decomposition time 12 min,acidity 11 mol/L,MnSO_4 dosage 10 g/L.The method can shorten decomposition time from 2 h to 12 min and reduce the analytical cost by using MnSO_4 as catalyst instead of Ag_2SO_4.Its accuracy and precision are essentially same as using Ag_2SO_4 as catalyst.The detection limit of COD is 65 mg/L.The method can analyze at one time several samples of great quantity.
出处 《化工环保》 CAS CSCD 北大核心 2004年第2期138-140,共3页 Environmental Protection of Chemical Industry
关键词 COD测定 催化剂 硫酸锰 开管法 chemical oxygen demand determination manganese sulfate opening-tube method
  • 相关文献

参考文献4

二级参考文献10

  • 1韦利杭.化学需氧量快速测定法的研究[J].环境污染与防治,1995,17(3):38-41. 被引量:38
  • 2尹淆.介绍处理COD的新技术[J].中国环境监测,1985,1(1):10-15.
  • 3黄叶丹,环境化学,1989年,3卷,5期,36页
  • 4张华民,环境化学,1989年,8卷,2期,64页
  • 5尹淆,中国环境监测,1985年,1卷,1期,10页
  • 6污染源统一监测分析方法编写组,污染源统一监测分析方法,1983年,45页
  • 7国际标准化组织 汇编,刘振庄.水与大气质量分析方法国际标准[M]中国环境科学出版社,1990.
  • 8《水和废水监测分析方法指南》编委会,.水和废水监测分析方法指南[M]中国环境科学出版社,1989.
  • 9张莘民,高明慧.化学需氧量的分析[J].环境化学,1989,8(2):62-69. 被引量:15
  • 10黄叶丹,赵华.COD测试方法的改进[J].环境保护,1992,20(4):34-34. 被引量:5