期刊文献+

用于等离子体诊断的ps激光探针 被引量:2

ps laser probe for laser plasma diagnosis
下载PDF
导出
摘要  ps激光探针作为激光等离子体诊断的探针光源,它是通过两次倍频和两次受激喇曼散射,将波长为1054nm、脉宽约为1ns激光转换成波长为308nm、脉宽小于30ps的紫外光。研究结果表明:探针光系统输出能量大于1mJ,脉宽小于30ps,均匀性较好,运行成功率大于90%,满足了激光等离子体诊断的要求。 The ps laser probe is a 308nm diagnostic light source for laser plasma diagnosis. It coverts a pulse of lns 1 054nm into a pulse of 263nm by double times frequency conversion, then it compresses 1ns to 30ps(FWHM) and the wavelength is shifted to 308nm by stimulated Raman scattering, at last the output laser is a pulse of output energy over 1mJ and 30ps.The experimental result is that the ps laser probe is output pulse of over 1mJ energy and 30ps(FWHM), and it runs over 90% stable rate, it accords with anticipated aim.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2004年第10期1274-1276,共3页 High Power Laser and Particle Beams
基金 国家863计划项目资助课题
关键词 倍频 喇曼散射 激光等离子体 激光探针 Frequency conversion Stimulated Raman scatter Laser plasma Laser probe
  • 相关文献

参考文献4

二级参考文献5

  • 1孟绍贤,光学学报,1985年,5卷,7期,640页
  • 2孟绍贤,物理学报,1985年,34卷,9期,1220页
  • 3孟绍贤,中国激光,1985年,12卷,11期,694页
  • 4孟绍贤,中国激光,1979年,6卷,4期,1页
  • 5孟绍贤,江志明,徐至展,张伟清.激光等离子体探针及应用研究[J].核聚变与等离子体物理,1989,9(2):102-106. 被引量:9

共引文献8

同被引文献15

  • 1高云凯,蒋运涛,李学春.基于孔径耦合带状线的激光脉冲整形系统[J].中国激光,2005,32(12):1619-1622. 被引量:7
  • 2郑坚 俞昌旋 等.全息干涉诊断等离子体电子密度的数值研究[J].强激光与粒子束,1997,9(2):173-177.
  • 3Mark D. Skeldon. Optical pulse-shaping system based on an electro-optic modulator driven by an aperture-coupled-stripline electrical-waveform generator [J]. J. Opt. Soc. Am. B, 2002, 19(10) :2423-2426.
  • 4M. D. Skeldon. A high-bandwidth electrical waveform generation based on an aperture coupled stripline [J]. Rev. Sci. Instrum. , 2000, 71(9):3559-3566.
  • 5Gabl E F, Failor B H, Bush G E, et al. Plasma evolution from laser-driven gold disks.1.Experiments and results[J]. Phys Fluids B, 1990, 2(10):2437-2447.
  • 6Prasad M K, Estabrook K G, Harte J A. Holographic interferograms from laser fusion code simulations[J]. Phys Fluids B, 1992, 4(6):1569-1575.
  • 7Benattar R, Popvics C, Sigel R. Polarized light interferometer for laser fusion studies[J]. Rev Sci Instrum, 1979, 50(12):1583-1585.
  • 8Buccellato R, Cunningham P F, Michaelis M M, et al. Comparative electron density measurements for the refractive diagnostic and Nomarski interferometry[J]. Laser and Particle Beams, 1992, 10(4):697-706.
  • 9王艳海,王江峰,李学春.高功率激光装置前端系统激光脉冲的时间整形及修正技术[J].光学学报,2007,27(3):477-481. 被引量:8
  • 10赵文怡,金国良,应再生,戴蓓兴,戴海平.基于有限差分束传播法的Mach-Zehnder型波导电光调制器的模拟设计[J].光子学报,1998,27(2):156-161. 被引量:7

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部