期刊文献+

磁共振肺通气-灌注成像诊断肺动脉栓塞的应用研究

下载PDF
导出
出处 《天津医科大学学报》 2004年第3期465-468,共4页 Journal of Tianjin Medical University
  • 相关文献

参考文献24

  • 1Salah D Qanadli, Mostafa El Hajjam, Benoit Mewsurolle, et al. Pulmonary Embolism detection: prospective evaluation of dual- section helical CT versus selective pulmonary arteriography in 157 patients[J ]. Radiology, 2000, 217:447
  • 2Amundsen T, Kvaerness J, Aadahl P, et al. A closed chest pulmonary artery occlusion/ reperfusion model in the pig: detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging [J] . Invest Radiol, 2000,35: 295
  • 3Prtrick Haage, Lawrence D, Rboert E, et al. Mechanical delivery of aerosolized Gadolinium - DTPA for pulmonary ventilation assessment in MR imaging[J]. Investigative Radiology,2001, 36(4):240
  • 4Mathias G, Gerhard L, Mark EL, et al. Dynamic 3D MR angiography of the pulmonary arteries in under four seconds[J ] .Journal of Magnetic Resonance Imaging, 2001, 13:372
  • 5Haage P, Jack knight, Shella D. et al. Aerosolized gadolinium -DTPA for demonstration of pulmonary ventilation in MR imaging of the lung[J ]. Fortschr Ronggenstr, 2000, 172:323
  • 6Misselwitz B, Hedlund Lw, Vock P, et al. Magnetic resonance imaging of pulmonary ventilation: initial experiences with a Gadolinium - DTPA - based aerosol[J ] . Investigative Radiology, 1997, 32:797
  • 7Patrick Haage,Gerhard Adam,Suleyman Karaagac, et al. Mechanical Delivery of Aerosolized Gadolinium - DTPA for Pulmonary Ventilation Assessment in MR imaging [J] . Invest Radiol, 2001, 36(4) :240
  • 8Kazuyoshi suga, Nobuhiko Ofasaware, Naofumi matsunaga, et al. Perfusion characteristics of Oleic Acid injured canine lung on Gd- DTPA enhanced dynamic MRI[J ] . Invest Radiology,2001, 36:386
  • 9Shi chang wang , Mats G,Wikstrom, et al. Evaluation of GaDTPA labeled dextran as an intravascular MR contrast agent:Imaging characteristics in normal rat tissues[J].Radiology,1990, 175: 483
  • 10Kazuyoshi suga, Masahiro M, Nobvuhiko Ogasawara, et al. Potential of Gd - DTPA - mannan liposome particles as a pulmonary perfusion MRI contrast agent [J ] . Invest Radiol,2001, 36(3): 136

二级参考文献8

  • 1Steiner P,McKinnon GC,Romanowski B,et al.Contrast-enhanced,ultrafast 3D pulmonary MR angiography in a single breath-hold: initial assessment of imaging performance[].Journal of Magnetic Resonance Imaging.1997
  • 2Gupta A,Frazer CK,Ferguson JM,et al.Acute pulmonary embolism:diagnosis with MR angiography[].Radiology.1999
  • 3Lentschig MG,Reimer P,Rausch Lentschig UL,et al.Breath-hold gadolinium-enhanced MR angiography of the major vessels at 1. 0 T:dose-response findings and angiographic correlation[].Radiology.1998
  • 4Hatabu H.MR pulmonary angiography and perfusion imaging: recent advances[].Seminars in Ultrasound CT and MR.1997
  • 5Meaney JF,Prince MR.Pulmonary MR angiography[].Magnetic Resonance Imaging.1999
  • 6Alley MT,Shifrin RY,Pelc NJ,et al.Ultrafast contrast-enhanced three-dimensional MR angiography: state of the art[].Radiographics.1998
  • 7Loubeyre P,Revel D,Douek P,et al.Dynamic contrast-enhanced MR angiography of pulmonary embolism: comparison with pulmonary angiography[].American Journal of Roentgenology.1994
  • 8Yucel EK.Pulmonary MR angiography: is it ready now[].Radiology.1999

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部