摘要
针对河南油田双河水厂混凝处理加药量偏大的情况,分析计算混凝处理各阶段的水力参数,模拟生产运行中的混合、反应和沉淀过程,进行室内模拟试验研究,并通过生产现场校核,得出针对不同原水水质加药处理的最佳投加量。通过实践证明:降低加药成本达75%,且水质提高效果显著。
AimingatthesituationthattheagentdoseaddedisabittoohighinthecoagulationtreatmentattheTwo鄄RiverWaterFactory,HenanOilField.Thehydraulicparameterofeachstageofthistreatmentisanalyzedandcalculated.Theprocessesofmixing,reactionandprecipitationintheoperationhavebeensimulated.Experi鄄mentalresearchofindoorsimulationiscarriedout.Theproductionsiteischeckedup.Thebestagentdosetobeaddedforrawwaterwithdifferentwaterqualityhasbeenobtained.Theresultsthroughpracticeshowthatthecostofagenttobeaddedisreducedby75%.Thewaterqualityisimprovedobviously.
出处
《工业水处理》
CAS
CSCD
2004年第10期62-64,共3页
Industrial Water Treatment
关键词
混凝
水力参数
模拟试验
coagulation
hydraulicparameter
simulatingtest