摘要  介绍了用4参数正弦波最小二乘拟合法评价线性测量系统直流偏移指标时,测量不确定度分析和评价过程.通过使用国军标GJB3756-1999'测量不确定度的表述及评定'中推荐的方法,讨论了影响评价结果不确定度的几个主要误差来源,包括信号源误差、采集序列的谐波失真、采集序列的噪声及非谐波失真、采集序列中信号周期的抖动、软件拟合运算误差的影响等,给出了直流偏移的测量不确定度及减小直流偏移指标评价不确定度的主要措施.在一个实际评价例子上,给出了直流偏移指标不确定度评价结果,表明该过程的正确性和切实可行性.该过程及结论可应用在对于计量标准进行直流偏移指标的不确定度分析上,也可用于估计直流偏移指标本身的不确定度. In this paper, it is described that the uncertainty of evaluation results of Offset of linear measurement system by using the least mean square four-parameter sine wave curve-fit method, including the courses of analysis and evaluation of uncertainty. By using the method from the Chinese military standard GJB 3756-1999 'expression and evaluation of uncertainty in measurement', some error sources of Offset evaluation are discussed, including the signal amplitude errors, the harmonic distortion of sampling serials, the quantization errors and noise and the spurious distortion, the jitter of the signal periods in sampling serials, the calculation errors of software, and the others. The uncertainty of offset of linear measurement systems is given, and several main methods about decreasing the offset evaluation errors and evaluation uncertainty are proposed. In an example of experiment, the analysis and uncertainty evaluation results of Offset by using the method in this paper are presented. The validation of the uncertainty shows the correctness and rightness of the method. The courses and conclusion of analysis and uncertainty evaluation of offset in this paper, can be applied to the uncertainty evaluation of measurement standards of Offset and the uncertainty evaluation of offset itself.
作者 梁志国
出处 《测试技术学报》 EI 2004年第3期253-258,共6页 Journal of Test and Measurement Technology
关键词 直流偏移 谐波失真 信号源 国军标 抖动 正弦波 序列 测量不确定度 线性测量系统 计量标准 metrology offset uncertainty analysis sine wave curve-fit methods evaluation calibration
  • 相关文献

参考文献10

  • 1叶德培 宋振国 等.GJB3756-1999,测量不确定度的表示及评定[M].北京:中国人民解放军总装备部军标出版发行部,1999,4..
  • 2Soulders T M. The Effects of Timing Jitter in Sampling Systems[J]. IEEE Transaction on Instrumentation and Mea-surement, 1990, 39(1): 80-85.
  • 3Liang Zhiguo, Zhu Jijie. A Digital Filter for the Single Frequency Sinusoid Series[J]. Transaction of Nanjing Uni-versity of Aeronautics & Astronautics, 1999, 16(2): 14-16.
  • 4John P, Deyst T, Soulders M, et al. Bounds on Least-Squares Four-Parameter Sine-Fit Errors Due to Harmonic Distortion and Noise[J]. IEEE Transaction on Instrumentation & Measurement, 1995, 44(3): 637-642.
  • 5Fluke Corporation. 5700A/5720A Series II Multifunction Calibrator Service Manual[Z]. 1996.
  • 6Liang Zhiguo, Lu Kejie, Sun Jingyu. Evaluation of Software of Four-Parameter Sine Wave Curve-fit[J]. Transa-ction of Nanjing University of Aeronautics & Astronautics, 2000, 17(1): 100-106.
  • 7JJF1057-1998.数字存储示波器: 中华人民共和国国家计量技术规范[S].[S].,..
  • 8JJF1048-1995.数据采集系统校准规范:中华人民共和国国家计量技术规范[S].[S].,..
  • 9梁志国.周期信号的谐波分析述评[J].计量技术,2003(2):3-5. 被引量:20
  • 10梁志国,孙璟宇,盛晓岩.正弦信号发生器波形抖动的一种精确测量方法[J].仪器仪表学报,2004,25(1):23-29. 被引量:19