期刊文献+

被服消毒除臭机消毒效果观察 被引量:4

OBSERVATION ON DISINFECTION EFFICACY OF CLOTHING DISINFECTION AND DEODORIZATION MACHINE
下载PDF
导出
摘要 观察BFJ-2000A型被服消毒除臭机的消毒效果,进行了载体定量杀菌试验与现场消毒试验。结果,被服消毒机启动连续作用60min,对布片上枯草杆菌黑色变种繁殖体平均杀灭率为99.99%。现场一床一袋消毒60min,对自然菌平均杀灭率为90.32%,2床一袋消毒60min,平均杀灭率为62.96%。结论,被服消毒机,采用一袋一床进行密闭消毒60min,密扎30min,消毒效果较理想。 In order to observe the disinfection efficacy of BFJ-2000A-type clothing disinfection and deodorization machine, carrier quantitative germicidal test and field disinfection trial were carried out. Results: Continuous operation of the clothing disinfection machine for 60 min killed 99.99% of vegetative form of Bacillus subtilis var. niger on cloth strip. In field trial, disinfection of one bed clothing in one bag for 60 min killed 90.32% of the natural bacteria in average. Disinfection of two bed clothing in one bag for 60 min killed 62.96% of the bacteria in average. Conclusion: Closed disinfection of one bed clothing in one bag for 60 min in the clothing disinfection machine and tightly ligating the bag for 30 min gave ideal disinfection efficacy.
作者 黄晓琴
出处 《中国消毒学杂志》 CAS 2004年第4期342-344,共3页 Chinese Journal of Disinfection
关键词 被服消毒机 枯草杆菌黑色变种 自然菌 臭氧 clothing disinfection machine Bacillus subtilis var. niger natural bacteria ozone
  • 相关文献

同被引文献17

引证文献4

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部