期刊文献+

Z-5000原子吸收光谱法检测血铅的方法学研究 被引量:12

Determination of Mood lead by atomic absorption method
下载PDF
导出
摘要 [目的]建立一种简便、快速、准确的血铅测定方法;检测农村儿童血铅水平。[方法]取全血0.5ml,用基体改进剂NH4H2PO4、TritonX-100和HNO3进行稀释;用Z-5000石墨炉原子吸收光谱仪,全自动进样方法进行测定。[结果]方法的测定限为1.40μg/L,相对标准偏差为1.95%-3.49%.回收率为89.99%-109.8%;已用于分析503例儿童血铅,结果满意。[结论]本法为一种理想的全血铅快速测定方法。 [Objective] To develop a simple, rapid and accurate method for determination of blood lead to detect blood lead level in children in rural area. [Methods] After the 0.5 ml blood was diluted by NH4H2PO4,TritonX-100 and HNO3,the blood level of lead was determined by atomic absorption method. [Results] The detection limit was 1.40μg/L, relative SD 1.95% - 3.49% and recovery 89.99% - 109.8%.Tie method had been successfully used in 503 children. [Conclusions] This method is good for determination of blood lead level.
出处 《中国卫生检验杂志》 CAS 2004年第5期528-530,共3页 Chinese Journal of Health Laboratory Technology
  • 相关文献

参考文献8

二级参考文献24

  • 1孙勤枢,侯士峰,陈钟道,朱军.电位溶出法同时测定水质和生物样品中的铜、铅、镉、锌、铁、锰[J].分析化学,1994,22(5):488-491. 被引量:34
  • 2沈晓明,周建德,高晓岚.微量血无火焰原子吸收光谱法血铅测定[J].微量元素与健康研究,1994,11(4):43-44. 被引量:27
  • 3王益昌.有机物的电化学分析[M].北京:中国石油化工出版社,1992.569.
  • 4[1]Committee on Measuring Lead in Critical Populations. Measuring lead exposure ininants,children and other sensitive population.Washington DC:National Academy Press,1993∶ 1-72.
  • 5[2]Shen XM,Rosen JF,Guo D, et al.Childhood lead poisoning in China.Sci Total Envir,1996, 181∶ 101-109.
  • 6[5]Centers for Disease Control.Preventing lead poisoning in young children.Atlanta:US Department of Health and Human Services,1991∶ 1-10.
  • 7[6]Markowitz M.Lead poisoning.Pediatrics in Review 2000,21(10)∶ 327-335.
  • 8[8]Centers for Disease Control and Prevention.Managing elevatred blood lead levels among young children:recommendations from the advisory committee on childhood lead poisoning prevention.Atlanta:US Department of Health and Human Services,2002∶ 1-123.
  • 9American Academy of Pediatrics, Committee on Environmental Health. Screening for elevated blood lead levels.Pediatrics,1998,110:1072-1078.
  • 10Schlenker Tl,Fritz Cj,Mark D,et al. Screening for pediatric lead poisoning: comparability of simultaneously drawn capillary and venous sample.JAMA,1994,271:1346-1348.

共引文献318

同被引文献101

引证文献12

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部