摘要
本文将电牵引供电系统中V/V接线变电所当作具有不对称串联阻抗的网络。运用三相对称分量法,分析计算V/V接线变电所牵引侧复故障。对该故障的分析指出和提供了一种新方法,而且概念清晰,步骤简单。
This paper regards the V/V connection railway traction substation in the tractive power supply system as the network with unsymmetrical series impedances, analyses three -phase fault on the substation using the method of symmetricalcomponents . The new analysis is indicated and supplied for this fault. And the concept is clear. The steps are simple.
出处
《华东交通大学学报》
1993年第4期9-15,共7页
Journal of East China Jiaotong University
关键词
牵引变电所
牵引侧复故障
短路事故
Fault calculation
UnsvmmetricaI series impedances
Traction substation