根据商茂广场中央空调系统的水质情况和管道垢成分的分析,采用了Mz-065粘泥剥离剂和Mz0130大分子螯合剂对系统进行清洗。清洗完成后,对系统进行了预膜处理,并开展了日常的加药保养工作,有效地防止了该系统的腐蚀和结垢,保证了中央空调正常、高效、节能运行。
According to the water quality and the analysis of pipe's scale of central air-condition system,the system was rinsed with MZ0301 slime-stripping agent and MZ0401 chelating agent.The system was pretreated with membrane technique and was miantained by adding erpssopm-proof agent and scale inhibitor;these measures guarantee the operation of cental air-condition system under normal,highly effective and economical conditions.