摘要 结合溪洛渡水电站工程实际情况,对影响水工混凝土抗冲耐磨性能的主要因素进行了探讨。对玄武岩人工骨料混凝土、硅粉混凝土、聚丙烯纤维混凝土、矿渣微粉混凝土、铁矿石混凝土及高性能抗冲耐磨混凝土的性能进行了试验研究,在此基础上推荐了适合溪洛渡水电站工程的抗冲耐磨混凝土。 In the light of Xiluodu Hydroelectric Project specific conditions,this paper probes into major factors affecting scour & wear resistance of hydraulic structure concrete.For this purpose concrete with crushed basalt aggregate,silica fume concrete,polypropylene fiber concrete,slag superfine cement concrete & highly scour & wear resisting concrete have been tested & studied.Based on the above study,scour & wear resisting concrete suitable for Xiluodu Hydroelectric Project is recommended.
出处 《水电站设计》 2004年第3期92-97,共6页 Design of Hydroelectric Power Station
关键词 抗冲耐磨混凝土 溪洛渡水电站 水工混凝土 人工骨料 硅粉混凝土 聚丙烯纤维混凝土 工程 土性 矿渣微粉混凝土 基础 concrete concrete test scour and resisting silica fume polyprophlene fiber slag superfine