期刊文献+

MSCT血管成像中Boluspro技术的应用 被引量:6

Application of Boluspro technique in MSCT angiography
下载PDF
导出
摘要 目的 :探讨腹部CTA时Boluspro技术中不同触发阈值对MSCT血管成像质量的影响 ,评价Boluspro技术在MSCTA中的应用价值。方法 :无明显循环系统疾病者 5例 ,标准量注射对比剂后 ,绘制主动脉强化上升期时间 密度曲线。40例患者行Boluspro触发CTA扫描 ,随机分成A、B、C三组 ,触发阈值分别设置为 12 0HU、15 0HU、180HU ,比较三组触发时间、实际触发值、主动脉强化值和MSCTA血管成像质量。结果 :40例均成功完成Boluspro自动触发扫描 ,A组和B组在触发时间和MSCTA血管成像质量评价上均无明显差异 ,但与C组有明显差异 ;三组的实际触发值均有明显差异 ,而CTA中主动脉强化值均无明显差异。结论 :Boluspro可以为MSCTA提供理想的延迟扫描时间 ,腹部CTA扫描时Boluspro技术选择主动脉阈值以 12 0~ 15 Objective:To assess the value of Boluspro tracker technique used in MSCT angiography,and to study the effect of different thresholds to MSCT angiography.Methods:Five volunteers without cardio-vascular disease underwent single-level dynamic scan at hepatic hilar level after bolus injection of routine dose contrast media,and the time-density curve of aorta in rising period was drawn from them.MSCT angiography was performed with Boluspro tracker in 40 patients,who were divided into three groups according to the tracker threshold of 120HU,150HU and 180HU respectively.The trigger time,trigger value,attenuation of aorta and the quality score of angiography in three groups were compared.Results:The Boluspro triggered the MSCT angiography scan successfully in all 40 cases.There was no significant difference between the trigger time,trigger value,attenuation of aorta and the quality score of angiography in group A and group B,but group C had longer trigger time than group A and B,and the quality score of angiography was less than the other group.Conclusion:Boluspro tracker in MSCT angiography is a reliable tool to determine optimal delayed time of scanning,which can offer high-quality images;the appropriate threshold in angiography of the abdominal arteries is about 120~150HU.
出处 《放射学实践》 2004年第10期756-759,共4页 Radiologic Practice
关键词 体层摄影术 X线计算机 血管造影术 图像处理 计算机辅助 Tomography,X-ray computed Angiography Image processing,computer assisted
  • 相关文献

参考文献10

  • 1Catalano C,Laghi A,Fraioti F,et al.High-resolution CT angiography of the abdomen[J].Abdom Imaging,2002,27(5):479-487.
  • 2Rubin GD,Shiau MC,Leung AN,et al.Aorta and Iliac arteries:single versus multiple detector-row helical CT angiography[J].Radiology,2000,215(3):670-676.
  • 3Byun J H,Kim TK,Lee SS,et al.Evaluation of the hepatic artery in potential donors for living donor liver transplantation by computed tomography angiography using multidetector-row computed tomography:comparison of volume rendering and maximum intensity projection techniques[J].J Comput Assist Tomogr,2003,27(2):125-131.
  • 4葛雅丽,郑敏文,龚雪鹏,张劲松,宦怡,石明国.血管同步计划技术在螺旋CT血管造影扫描中的应用[J].第四军医大学学报,2002,23(9):844-846. 被引量:4
  • 5Riederer SJ,Bernstein MA,Breen JF,et al.Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering:design specifications and technical reliability in 330 patient studies[J].Radiology,2000,215(2):584-593.
  • 6Huston J,Fain SB,Riederer SJ,et al.Carotid arteries:maximizing arterial to venous contrast in fluoroscopically triggered contrastenhanced MR angiography with elliptic centric view ordering[J].Radiology,1999,211(1):265-273.
  • 7尹建忠,沈文,边铁城,张萍,祁吉.肝脏多层螺旋CT血管成像的期相设置与优化[J].中华放射学杂志,2003,37(6):551-555. 被引量:33
  • 8吴东,周康荣,陈祖望.螺旋CT门静脉造影延迟时间的合理选择[J].临床放射学杂志,1999,18(5):272-276. 被引量:36
  • 9Brancatelli G,Katyal S,Federle MP,et al.Three dimensional multislice helical computed tomography with the volume rendering technique in the detection of vascular complications after liver transplantation[J].Transplantation,2002,73(2):237-242.
  • 10Vade A,Olson MC,Vittore CP,et al.Hepatic enhancement analysis in children using Smart Prep monitoring for 2:1 pitch helical scanning[J].Pediatr Radiol,1999,29(9):689-693.

二级参考文献15

  • 1严福华 曾蒙苏 等.肝脏螺旋CT检查技术参数的选择[J].临床放射学杂志,1996,15:290-293.
  • 2严福华,临床放射学杂志,1996年,15卷,290页
  • 3Hui HU. Multi-slice helical CT: scan and reconstruction. Med Phys, 1999, 26: 5-18.
  • 4Shimizu T, Misaki T, Yamamoto K, et al. Helical CT of the liver with computer-assisted bolus-tracking technology: scan delay of arterial phase scanning and effect of flow rates. J Comput Assist Tomogr, 2000, 24: 219-223.
  • 5Frederick MG, McElaney BL, Singer A, et al. Timing of parenchymal enhancement on dual-phase dynamic helical CT of the liver: how long does the hepatic arterial phase predominate? AJR, 1996, 166: 1305-1310.
  • 6Han JK, Kim AY, Lee KY, et al. Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model. J Comput Assist Tomogr, 2000, 24: 400-406.
  • 7Kopka L, Rodenwa J, Fischer U, et al. Dual-phase helical CT of the liver: effect of bolus tracking and different volumes of contrast material. Radiology, 1996, 201: 321-326.
  • 8Luboldt W, Straub J, Seemann M, et al . Effective contrast use in CT angiography and dual-phase hepatic CT performed with a subsecond scanner. Invest Radiol, 1999, 34: 751-760.
  • 9Nino-Murcia M, Olcott EW, Jeffrey RB Jr, et al. Focal liver lesions: pattern-based classification scheme for enhancement at arterial phase CT. Radiology, 2000, 215: 746-751.
  • 10Weg N, Scheer MR, Gabor MP. Liver lesions: improved detection with dual-detector-array CT and routine 2.5 mm thin collimation. Radiology, 1998, 209: 417-426.

共引文献70

同被引文献36

引证文献6

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部