摘要
介绍了单压汽轮机配双压余热锅炉的联合循环电厂在低负荷运行时会出现低压蒸汽产量相对过剩问题,分析了问题产生的机理,并提出了解决措施,并介绍了在工程中的应用实例。
It is pointed out that low pressure steam generation will be excess when the unit is running at low load condition in a combined cycle power plant consisting of a single-pressure ST and dual-pressure HRSG. The cause is analyzed. At meantime, some measures are introduced to solve the problem. Finally, one practical case is shown.
出处
《电站系统工程》
北大核心
2004年第5期22-23,共2页
Power System Engineering