基于正序故障分量的方向元件性能分析 被引量:3

Analysis of the directional relay performance based on the positive-sequence fault components
下载PDF
导出
摘要 基于正序故障分量的方向继电器是一种新型故障方向判别元件。为全面了解该元件的工作性能,在500kV输电系统模型上,对振荡伴随不同类型短路和非全相运行情况下方向元件的动作行为进行仿真计算和分析。仿真结果表明,基于正序故障分量的方向元件适应于所有故障类型,不受负荷电流影响,无电压死区,灵敏度高。 The positive-sequence fault components based directional relay is a new type of unit for recognizing fault direction. To understand the relay's performance comprehensively, this paper carries on the simulation calculation and analysis under the conditions of different fault types accompanied with power oscillation and incomplete phase operation on a 500 kV transmission line model. The simulation results show that this new directional relay can adapt to all transmission line fault types. Moreover, its behavior is not affected by load current, and it has no voltage dead zone and owns a high sensitivity.
出处 《继电器》 CSCD 北大核心 2004年第18期33-37,共5页 Relay
关键词 方向元件 正序故障分量 负荷电流 非全相运行 输电系统 短路 动作行为 性能分析 仿真结果 死区 directional relay positive-sequence component fault component simulation calculation
  • 相关文献

参考文献4

  • 1张志竟 黄玉铮(ZHANGZhi-jing HUANGYu-zheng).电力系统继电保护原理与运行(The Theory and Operation of Power System Protective Relaying)[M].北京:中国电力出版社(Beijing:China Electric Power Press),1995..
  • 2葛耀中(GEYao-zhong).新型继电保护与故障测距原理与技术(NewTypesofProtectiveRelayingandFaultLocationwithTheirTheoryandTechniques)[M],Xi'an Jiaotong University Press)[M].西安:西安交通大学出版社(Xi'an,1996..
  • 3高厚磊,文锋,王广延,陈革.两种多相补偿阻抗继电器动作性能的数字分析[J].继电器,1995,23(3):3-9. 被引量:3
  • 4刘万顺(LIUWan-shun).电力系统故障分析(PowerSystemFaultAnalysis)[M],China Electric Power Press)[M].北京:中国电力出版社(Beiing,1998..

二级参考文献2

  • 1李晓明.一种新的接地多相补偿阻抗继电器[J]继电器,1987(01).
  • 2朱声石.两类距离继电器的协同工作[J]电力系统自动化,1980(01).