一厂房出现严重不均匀沉降,经对基础采取静力压桩进行加固纠偏后,沉降趋于稳定,厂房的偏斜得 到了部分纠正。介绍加固纠编方案设计以及静压桩的施工工艺和施工注意事项。
Serious non-uniform subsidence occurred in a workshop. After strengthening and rectification of the foundation by static pressure pile, the subsidence went nearly halt and the deviation was partially rectified. An introduction is given to strengthening and rectification design, and construction technology of static pressure pile and points for attention.
出处
《铁道建筑技术》
2004年第5期56-58,共3页
Railway Construction Technology