摘要
针对山东邹县发电厂两台2020t/h燃煤锅炉分隔屏频繁爆漏现象,结合锅炉的结构、设备存在的问题以及燃烧工况现状,系统地分析了造成分隔屏爆漏的原因,从而提出了防止措施。
In connection with burst leakages, that often happened to the sectional devided platens of Shandong Zhou County Power Plant's two 2020t/h coal firing boilers, the causes that effected the bursting accidents as well as precautionary measures are systematically analyzed from the point of view of boiler construction, equipment deficiencies and condition of combustion.
出处
《发电设备》
2004年第6期373-375,381,共4页
Power Equipment
关键词
燃煤锅炉
分隔屏
爆漏原因
分析
coal firing boiler
sectional divided platen
causes of explosion
analysis