期刊文献+

闭式环流高功率连续CO_2激光器的不稳定性问题

On the instability problem of close circular flow high power continuous CO2 laser
下载PDF
导出
摘要 本文讨论了导至“闭式环流高功率连续CO_2激光器”输出功率不稳定性的主要因素,特别对等离子体的电离不稳定性进行了较深入的分析;在一台管(阴极)板(阳极)结构的闭式环流高功率连续CO_2激光器上做实验,研究了输出功率的不稳定度(△P/)与有关因素(杂质气体、冷却水温等)的关系;提出了几点具有现实意义的技术措施,可以有效地减少高功率CO_2激光的不稳定性。 In this paper, the main factors, which cause the instability of output power of 'close circular flow high power continuous CO2 laser',are discussed. The ion-ization instability of plasma more deeply is analysed, particularly. The experiments are made on the close circular flow high power continuous CO2 laser with construction of the tube (cathode) and the plates (anode). The relation of a degree of output power insta-bility (△P/P) and the relative factors (the impurity gas, the temperature of cooling water, etc. ) is researched. The several technical measures with an actual significace are presented. These tcehnical measures may effectually reduce the instability of output power of high power continuous CO2 laser.
作者 殷一贤
出处 《激光杂志》 EI CAS CSCD 北大核心 1993年第6期299-302,共4页 Laser Journal
关键词 高功率 CO2激光器 输出功率 稳定性 close circular flow high power continuous CO2 Isaer, output power, in-stability,plasma