摘要 分析了宝钢电厂1#机组公用400VP/C母线电源自动切换逻辑,指出了一例1#机组公用400VP/C母线电源自动切换失败的原因,并提出了对切换逻辑的改进意见。通过改进,提高了母线自动切换的可靠性,同时对母线电源切换的一般原则进行了探讨。 The power auto switching principle of public 400 V P/C bus for No.1 generating unit of the Power Plant of Bao Steel Co. Ltd. Was analyzed. The failure causes of the power auto switching of the bus were pointed out and the improving opinions for the switching principle were put forward. Through improvement, the reliability of the bus auto switching was increased, and at the same time the general principle of the power switching of the bus was discussed.