期刊文献+

1609补偿声波测井仪发射电路的改进 被引量:1

Improvement on the transmitting circuits of 1609 acoustic logging tool
下载PDF
导出
摘要 文章针对 1 6 0 9补偿声波测井仪发射电路稳定性差、压控元件易击穿等问题提出改进方法 ,用可控硅代替原来的CMOS场效应管来改善仪器的工作性能。实际应用表明 ,改进后的仪器工作性能和技术指标稳定 ,很好地满足了生产需要。 A way of improving the poor stability and the easy breakdown of the voltage controlled components in the electronics circuit of the transmitting part of the 1609 acoustic log instrument is suggested in the paper. The work function of the instrument is improved by using silicon controlled rectifier to replace the original CMOS field effect transistor. The practice results show that the improvement makes the instrument stable and reliable in function and technique index of the tool, and so it meets the demand of logging better.
出处 《石油仪器》 2004年第5期39-40,43,共3页 Petroleum Instruments
关键词 CMOS管 发射电路 可控硅 逻辑脉冲 孔隙度 CMOS transistor, transmitting circuit, silicon controlled rectifier(SCR), logical pulse, porosity.
  • 相关文献

参考文献2

  • 1康华光.电子技术基础摸拟部分(第三版)[M].北京:高等教育出版社,1991
  • 2扬礼英,陆六刚.测井仪器[M].北京:石油工业出版社,1982

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部