摘要 目的 :探讨多层螺旋CT(MSCT)冠状动脉成像技术的临床应用。方法 :对 2 1例可疑冠状动脉病变患者进行螺旋CT扫描 ,采用回顾性心电门控技术 ,主机用SnapShotSegment程序获得原始资料及AW 4 1工作站图像后处理 ,重建出各主要血管 ,并分析血管狭窄和闭塞程度。结果 :MSCT冠状动脉血管成像对冠状动脉近中段显示清晰 ,显示率达 89%以上 ;对冠状动脉狭窄显示良好 ,与临床符合率达 92 6 %。 5支搭桥血管中有 1支可见 >80 %的狭窄。结论 :MSCTA作为非侵入性冠状动脉血管成像技术 ,可作为评价冠状动脉病变的重要筛选方法。 Objective:To study the clinical application and of multislice spiral computer tomography angiography(MSCTA) in coronary artery.Methods:21 patients underwent examination of spiral CT.All volume data come from retrospectively ECG-gated multislice spiral row CT angiography were transferred to AW4.1 computer workstation for reconstraction.The patency of coronary artery and other branches were examined.The distribution and extend of coronary aterial stenosis were analyzed.Results:MSCTA showed the middle part of coronary vessels clearly,the displaying rate was over 89%.It was a good method in diaplaying coronary artery stenosis which coincided with clinical diagnosis over 92.6%.one of the five graft were revealed about 80% stenosis.Conclusion:MSCTA as a non-invasive examination is a valuable method in detecting the disease of coronary artery.
出处 《内蒙古医学杂志》 2004年第10期744-746,共3页 Inner Mongolia Medical Journal
关键词 多层螺旋CT 冠状动脉 血管造影术 MSCT Coronay artery Angiography
  • 相关文献

参考文献8

  • 1段青,薛蕴菁,王华,邹松.多层螺旋CT在冠状动脉支架术后的应用[J].心血管康复医学杂志,2003,12(5):389-390. 被引量:42
  • 2Windecker S, Maier - Rudolph W, Bonld T, et al. Interventional cardlology,in Europe 1995. Working Group Coronary Circnlation of the European Society of Cardiology[J ]. Eur Heart J, 1999,20 :484.
  • 3Rubin CD,Dake MD,Semba CP. Current status of three-dimensional spiral CT scanning for imaging the vasculature [ J ]. Radiol Clin North Am, 1995,33 : 51.
  • 4张欢,杜联军,宋琦,潘自来,凌华威,方文强,朱理敏,吴振芳,董海鹏,陈克敏.多层螺旋CT冠状动脉钙化积分初探[J].临床放射学杂志,2001,20(10):757-759. 被引量:20
  • 5Nieman K, Rosing B, Van Gens RM, et al. Usefulness of multislice coronary artery disease[J] .Am J Cardial,2002,89(4) :913.
  • 6Ropers D, Ulzheimer S, Wenkel W, et al. Invertigation of aortocoronary artery bypass graft by multislice spiral computer tomography with electrocardlographyic-galed image reconstruction [J].Am J Cardiol,2001,88(2) :792.
  • 7Hong C, Beeker CR, Huber A, et al, ECG - gated reconstructed multidetector row CT coronary angiography: effect of varying trigger delay on image quality[J ]. Radiology, 2001,220: 712.
  • 8Nieman K, Rensing BJ, Van Geuns RJ, et al. Non - invasive coronary angiography with multislice spiral computer tomography [J ].Impact of Heart Rate Heart,2002,88 : 470.

二级参考文献7

  • 1[1]Wang ZQ, Zhu H, Xia K, et al.Preliminary application of MSCT of coronary artery[J].Journal of Computed Tomography,2001,10:10-12.
  • 2[2]Pump H, Mohlenkamp S, Sehnert CA, et al.Coronary arterial stent patency:assessment with electron-beam CT[J].Radioligy,2000,221(21):447-452.
  • 3[3]Nieman K, Rensing BJ,Van Genus RJ, et al.Usefulness of multislice computed tomography for detecting obstructive coronary artery disease[J].Am J Cardiol,2002,89(8):913.
  • 4[4]Vogl TJ, Abolmaali ND, Diebold T, et al.Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography[J].Radiology,2002,223(1):212-220.
  • 5[5]Urban BA, Ratner LE, Fisdrian EK.Three-dimensional volume-rendered CT angiography of renal arteries and veins:normal anatomy, variants, and clinical applications[J].Radiographics,2001,21(2):373-386.
  • 6[6]Addis KA, Hopper KD,lyriboz TA, et al.CT angiography:in vitro comparison of five reconstruction methods[J].Am,2001,177(5):1171-1176.
  • 7张闽光,王嵩,沈天真,陈星荣,冯晓源.对电子束CT冠状动脉钙化评分准确性的评价[J].中国医学计算机成像杂志,1998,4(4):238-239. 被引量:2