期刊文献+

MR检查时人体内生物医学置入物和置入设备的安全性研究进展及对策 被引量:11

原文传递
导出
出处 《中华放射学杂志》 CAS CSCD 北大核心 2004年第9期999-1001,共3页 Chinese Journal of Radiology
  • 相关文献

参考文献14

  • 1Shellock FG,Crues JV 3rd.MR safety and the American College of Radiology White Paper.AJR,2002,178: 1349-1352.
  • 2Shellock FG,Tkach JA,Ruggieri PM,et al.Aneurysm clips: evaluation of magnetic field interactions and translational attraction by the use of ''long-bore'' and ''short-bore'' 3.0-T MR imaging systems.Am J Neuroradiol,2003,24: 463-471.
  • 3Shellock FG.Biomedical implants and devices: assement of magnetic field interactions with a 3.0-Tesla MR system.J Magn Reson Imaging,2002,16: 721-732.
  • 4Shellock FG.Magnetic resonance safety update 2002: implants and devices.J Magn Reson Imaging,2002,16: 485-496.
  • 5Sawyer-Glover A,Shellock FG.Pre-MRI procedure screening: recommendations and safety considerations for biomedical implants and devices.J Magn Reson Imaging,2000,12: 92-106.
  • 6Sommer T,Vahlhaus C,Lauck G,et al.MR imaging and cardiac pacemakers: in-vitro evaluation and in-vivo studies in 51 patients at 0.5 T.Radiology,2000,215: 869-879.
  • 7Kangarlu A,Shellock FG.Aneurysm clips: evaluation of magnetic field interactions with an 8.0 T MR system.J Magn Reson Imaging,2000,12: 107-111.
  • 8Hug J,Nagel E,Bornstedt A,et al.Coronary arterial stents: safety and artifacts during MR imaging.Radiology,2000,216: 781-787.
  • 9Hennemeyer CT,Wicklow K,Feinberg DA,et al.In vitro evaluation of platinum Guglielmi detachable coils at 3 T with a porcine model: safety issues and artifacts.Radiology,2001,219: 732-737.
  • 10Shellock FG,Shellock VJ.Metallic stents: evaluation of MR imaging safety.AJR,1999,173: 543-547.

同被引文献135

  • 1廖丹玲,梁碧玲,黄穗乔.体内置入物对MR检查安全性的影响[J].中华放射学杂志,2005,39(6):573-575. 被引量:11
  • 2戴永雨,张晶,高培毅,何志华.牙科金属对头部磁共振成像的影响[J].中华放射学杂志,1996,30(6):409-409. 被引量:4
  • 3陈宝峰,徐新.起搏器及植入型心律转复除颤器患者磁共振成像检查的安全性及相容性[J].中华心律失常学杂志,2007,11(1):75-78. 被引量:7
  • 4Hug J, Nagel E, Bornstedt A, et al. Coronary arterial stent : safety and artifacts during MR imaging [ J ]. Radiology, 2000,216 ( 3 ) :781 - 787.
  • 5Shellock FG, Morisoli S, Kanal E. procedures and biomedical implants, materials, and devices: 1993 update [ J]. Radiology, 1993, 189(2) : 587 -599.
  • 6Shellock FG, Crues JV 3^rd. MR safety and the American College of Radiology White Paper[ J ]. AJR,2002,178 (6) : 1349 - 1352.
  • 7Gerber TC, Fasseas P, Lennon RJ, et al. Clinical safety of magnetic resonance imaging early after coronary artery stent placement [ J ]. J Am Coll Cardiol,2003, 42(7) :1295 -1298.
  • 8Porto I, Selvanayagam J, Ashar V, et al. Safety of magnetic resonance imaging one to three days after bare metal and drug - eluting stent implantation [ J ]. Am J Cardiol,2005,96 ( 3 ) : 366 - 368.
  • 9Shellock FG. Magnetic resonance safety update 2002: implants and devices [ J ], Magn Reson Imaging, 2002,16 ( 5 ) :485 - 496.
  • 10Shellock FG, Forder JR . Drug - eluting coronary stent: in vitro evaluation of magnet resonance safety at 3 Tesla[ J]. Cardiovasc Magn Reson,2005,7(2) : 415 -419.