摘要
介绍了12 0 0低压轴径向节能型氨合成塔内件基本结构、催化剂的装填情况和升温还原过程 ,总结了该塔实际运行效果和生产操作经验。
Basic structure,filling situation of catalyst and heating and reducing processes were introduced for 1 200 low pressure axi al & radial energy saving type of ammonia converter internal,actually operatin g effect and productive operation experience for this converter were also summar ized.
出处
《化肥设计》
CAS
2004年第3期36-38,共3页
Chemical Fertilizer Design
关键词
轴径向氨合成塔
内件结构
催化剂装填
升温还原
axial and radial ammonia converter
structure of in ternal
filling of catalyst
heating and reducing