硬度可变式结肠镜的临床评价 被引量:1

原文传递
导出
出处 《中华消化内镜杂志》 2004年第4期281-283,共3页 Chinese Journal of Digestive Endoscopy
  • 相关文献

参考文献6

  • 1平田一郎 佐々木伸一 中川意 他.新しい内視镜の特徵と挿入法硬度可变式细径大腸内視镜(CF—240AI)の挿入法と臨床評価[J].早期大腸癌,2000,4:75-81.
  • 2松永厚生 野村美樹子 石田一彦 他.安全で苦痛の少ない大腸内視镜挿入法—スコ一プの選択と適応症例[J].消化器内視鏡,2003,15:1592-1596.
  • 3池芝盛,编译.内分泌基础与临床.北京:科学技术出版社,1987,661.
  • 4工藤進英 主編.大腸内視鏡插入法-ビギナ一かうベテランまで[Z].東京:医学書院,1997.18.
  • 5安藤正夫 三島利之 小澤俊文.他硬度可変式细径大腸内視镜(CF—240AI)を用いたtotal colonoscopyの検討[J].早期大腸癌,2000,4:69-73.
  • 6町田マキョ 佐竹儀治.硬度可变式大腸内視镜は有用か[J].消化器内視鏡,2003,15:1627-1632.

同被引文献14

  • 1Mitchell RM, McCallion K, Gardiner KR, Watson RG, Collins JS. Successful colonoscopy; completion rates and reasons for incompletion. Ulster Med ] 2002; 71:34-37 [PMID: 12137162].
  • 2Cardin F, Minicuci N, Andreotti A, Pinetti E, Campigotto F, Dona BM, Martella B, Terranova O. Maximizing the general success of cecal intubation during propofol sedation in a multi-endoscopist academic centre. BMC Gastroenterol 2010; 10:123 [PMID: 20961451 DOh 10.1186/1471-230X-10-123].
  • 3Banks MR, Haidry R, Butt MA, Whitley L, Stein J, Langrnead L, Bloom SL, O'Bichere A, McCartney S, Basherdas K, Rodriguez-Justo M, Lovat LB. High resolution colonoscopy in a bowel cancer screening program improves polyp detection. World J Gastro- enterol 2011; 17:4308-4313 [PMID: 22090787 DOI: 10.3748/wjg.v17.i38.4308].
  • 4Sola-Vera J, Uceda F, Brotons A, Saez J, Girona E, P6rez E, Pice MD, Grau C, Sillero C. Does the use of a variable stiffness colonoscope offer advantages during colonoscopy under deep sedation? Results of a randomized trial. Eur J Gastroenterol Hepatol 2011; 23:593-597 [PMID: 21593674 DOI: 10.1097/ MEG.0b013e32834793d3].
  • 5Xie Q, Chen B, Liu L, Gan H. Does the variable- stiffness colonoscope makes colonoscopy easier? A meta-analysis of the efficacy of the variable stiffness colonoscope compared with the standard adult colonoscope. BMC Gastroentero12012; 12:151 [PMID: 23095461 DOE 10.1186 /1471-79,13X-17-1511.
  • 6Baumann UA. Does retroflexion improve adenomaI miss rates on the right side of the colon when using a pediatric variable-stiffness colonoscope during routine colonoscopy? Endoscopy 2009; 41:654 [PMID: 19588295 DOI: 10.1055/s-0029-1214876].
  • 7East JM. Effect of a proprietary intraluminal stiffen- ing wire device on cecal intubation time and rate with used colonoscopes; a randomized, controlled trial. BMC Res Notes 2013; 6:48 [PMID: 23379922 DOI: 10.1186/1756-0500-6-48].
  • 8Kaffes AJ, Mishra A, Ding SL, Hope R, Williams SJ, Gillespie PE, Bourke MJ. A prospective trial of variable stiffness pediatric vs. standard instrument colonoscopy. Gastrointest Endosc 2003; 58:685-689 [PMID: 14595301].
  • 9Prieto-de-Frias C, Muaoz-Navas M, Carretero C, Carrascosa J, Bet6s MT, De-la-Riva S, Herraiz MT, Stibtil JC. Comparative study of a responsive insertion technology (RIT) colonoscope versus a variable-stiffness colonoscope. Rev Esp Enferm Dig 2013; 105:208-214 [PMID: 23859449].
  • 10Saunders BP, East JE. What are the benefits of the variable-stiffness colonoscope? Nat Clin Pract Gas- troenterol Hepatol 2008; 5:8-9 [PMID: 17971796].

引证文献1

二级引证文献4