NON-INVASIVE IMAGING OF CORONARY ARTERY WITH 16-SLICE SPIRAL COMPUTED TOMOGRAPHY 被引量:6

NON-INVASIVE IMAGING OF CORONARY ARTERY WITH 16-SLICE SPIRAL COMPUTED TOMOGRAPHY
下载PDF
导出
摘要 To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensation 16, Siemens, Germany) in 230 patients with suspected coronary heart disease (CHD). Parameters of the plain scan were: 120 kV, 133 mA, slice col-limation 16 mm×1.5 mm, rotation time 0.42 seconds, increment 1.5 mm, and slice width 3 mm. Parameters of the enhanced scan were: 120 kV, 500 mA, slice collimation 16 mm×0.75 mm, rotation time 0.42 seconds, increment 0.5 mm, and slice width 1 mm. Enhanced CT scan was performed with a rapid intravenous injection of 100 mL iothalamate meglumine (Ultravist) (370 mgI/mL) or Omnipaque (350 mgI/mL) and 30 mL 0.9% NaCl chaser bolus at a flow rate of 3.5 mL/s. Calcium scoring with plain scan images and two and three dimensional reconstruction with enhanced scan images were made in all cases, among which 30 cases underwent conventional coronary angiography. Demonstration of coronary arteries and their stenosis were evaluated and the factors that might influence the image quality were analyzed. Results Coronary calcium scores were calculated and coronary artery was demonstrated in our study. In the evaluationof image quality with volume rendering technique (VRT) images, 78.3% of the images were of the first class, 12.2% the sec-ond class, and 9.6% the third class. Multi-planar reconstruction (MPR) and maximal intensity projection (MIP) were better than VRT in the demonstration of small branches. The image quality was related to the heart rate, with or without arrhythmia, and breath-hold ability of patients. Comparative study of the stenosis of coronary arteries in 30 cases showed that the sensi-tivity and specificity of 16-slice coronary CT angiography (CTA) to diagnose significant stenosis were 95.8% and 94.8% resp-ectively. Conclusion As a non-invasive and quick method, 16-slice coronary CTA is sensitive and specific to diagnose the stenosis of coronary arteries and can be used as a screening method in the diagnosis of CHD. To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensation 16, Siemens, Germany) in 230 patients with suspected coronary heart disease (CHD). Parameters of the plain scan were: 120 kV, 133 mA, slice col-limation 16 mm×1.5 mm, rotation time 0.42 seconds, increment 1.5 mm, and slice width 3 mm. Parameters of the enhanced scan were: 120 kV, 500 mA, slice collimation 16 mm×0.75 mm, rotation time 0.42 seconds, increment 0.5 mm, and slice width 1 mm. Enhanced CT scan was performed with a rapid intravenous injection of 100 mL iothalamate meglumine (Ultravist) (370 mgI/mL) or Omnipaque (350 mgI/mL) and 30 mL 0.9% NaCl chaser bolus at a flow rate of 3.5 mL/s. Calcium scoring with plain scan images and two and three dimensional reconstruction with enhanced scan images were made in all cases, among which 30 cases underwent conventional coronary angiography. Demonstration of coronary arteries and their stenosis were evaluated and the factors that might influence the image quality were analyzed. Results Coronary calcium scores were calculated and coronary artery was demonstrated in our study. In the evaluationof image quality with volume rendering technique (VRT) images, 78.3% of the images were of the first class, 12.2% the sec-ond class, and 9.6% the third class. Multi-planar reconstruction (MPR) and maximal intensity projection (MIP) were better than VRT in the demonstration of small branches. The image quality was related to the heart rate, with or without arrhythmia, and breath-hold ability of patients. Comparative study of the stenosis of coronary arteries in 30 cases showed that the sensi-tivity and specificity of 16-slice coronary CT angiography (CTA) to diagnose significant stenosis were 95.8% and 94.8% resp-ectively. Conclusion As a non-invasive and quick method, 16-slice coronary CTA is sensitive and specific to diagnose the stenosis of coronary arteries and can be used as a screening method in the diagnosis of CHD.
出处 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期174-179,共6页 中国医学科学杂志(英文版)
关键词 非入侵成像 冠状动脉 16-切片 螺旋层析X射线摄影术 血管造影术 angiography tomography, X-ray computed coronary artery
  • 相关文献

参考文献10

  • 1[1]Agatston AS, Janownz WR, Hildner FJ, et al. Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 1990;15:827-32.
  • 2[2]Xiao Y, Tian JM, Wang P J, et al. Multi-slice spiral CT coronary angiography: technique and clinical applications. Chin J Radiol2002;36:357-61.
  • 3[3]Vogl TJ, Abolmaali ND, Diebold T, et al. Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 2002;223:212-20.
  • 4[4]Nieman K, Rensing B J, van Geuns RM, et al. Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 2002;88:470-4.
  • 5[5]Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 2002; 106:2051-4.
  • 6[6]Achenbach S, Giesler T, Ropers D, et al. Detection of coronary artery stenosis by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography. Circulation 2001;103:2535-8.
  • 7[7]Morgan-Hughes GJ, Marshall AJ, Roobottom CA, et al. Multislice computed tomographic coronary angiography: experience in a UK centre. Clin Radiol 2003;58:378-83.
  • 8[8]Cademartiri F, Mollet N, van der Lugt A, et al. Non-invasive16-row multislice CT coronary angiography: usefulness of saline chaser. Eur Radiol 2004; 14:178-83.
  • 9[9]Leber AW, Knez A, Becker C, et al. Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography. Heart 2003;89:633-9.
  • 10[10]Nieman K, van der Lugt A, mt Pattynama P, et al. Noninvasive visualization of atherosclerotic plaque with electron beam and multislice spiral computed tomography. J Interven Cardiol 2003;16:123-8.