1200m^3/d电镀废水膜法回收工程 被引量:22

Electroplating effluent recover treatment project with1200m 3 /d
下载PDF
导出
摘要 在中试基础上建立1200m3/d电镀镍漂洗水膜法回收工程,采用三级膜分离技术浓缩电镀废水并回收水和镍.一级处理量50m3/h,浓缩10倍;二级处理量5m3/h,浓缩5倍;三级处理量1m3/h,浓缩2倍以上,共浓缩100倍以上.一级膜分离系统对镍的截留率为98%;二级、三级膜分离系统对镍截留率均在99%以上.从2001年1月至2002年12月,共运行了2年.三级膜分离系统的通量均有不同程度的下降,一级下降约20%,二级下降约25%,三级下降约40%.整个系统运行良好,基本上实现了电镀废水的资源化. On the basis of successful experiments,a project with1200m 3 /d for treating electroplating nickel patching liquor,concentrates and recovers nickel and water with three steps membrane separation technology.The treatment's content of first step is50m 3 /h,concentrate10times;respectively,the second is50m 3 /h,and concentrate5times;the third is1m 3 /h,and concentrate more than2times.The total concentration excesses100times.The nickel reject of first step is over98%,both the second and the third are more than99%.The system runs from2001.1to2002.12.There're some different degree descend in permeating flux of each step membrane system.The first grade permeating flux shut down20%,the second shut down25%,and the third shut down about40%.The performance of the project is good.Consequently it may be concluded that electroplating wastewater can be reclaimed.
出处 《膜科学与技术》 CAS CSCD 北大核心 2004年第5期43-46,共4页 Membrane Science and Technology
基金 国家"十五"科技攻关项目(2002BA313B07)
关键词 电镀废水 膜法回收 膜分离技术 截留率 通量 electroplating wastewater membrane separation technology rejection permeate flux
  • 相关文献

参考文献1

二级参考文献4

  • 1高以xuan 叶凌碧.膜分离技术基础[M].上海:科学出版社,1989.317-330.
  • 2(美)Zahid Amjad 殷琦等(译).反渗透-膜技术.水化学和工业应用[M].北京:化学工业出版社,1999.278-280.
  • 3俞三传,张建飞,蔡惠如.纳滤[J].膜科学与技术,1999,19(2):1-5. 被引量:39
  • 4谭永文,沈炎章,卢光荣,石雷.嵊山500吨/日反渗透海水淡化示范工程[J].水处理技术,2000,26(1):1-6. 被引量:29

共引文献41

同被引文献217

引证文献22

二级引证文献178

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部