摘要 Mass spectrometer is connected through an adaptor to a sealed small battery to probe the gas phase changes inside the battery. The factors influencing the response time are analyzed with a simplified model. The feasibility of the new technique is demonstrated with a Ni-Cd battery, showing different profiles of MS intensities for O2 and H2. Compared with gas chromatography, this technique has the advantage of being noninvasive and should be useful for the study and diagnostic examination of small sealed batteries.
机构地区 DepartmentofChemistry
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第7期823-826,共4页 中国化学快报(英文版)
关键词 Mass spectroscopy gas evolution BATTERIES OVERCHARGE noninvasive. Mass spectroscopy, gas evolution, batteries, overcharge, noninvasive.
  • 相关文献

参考文献8

  • 1[1]M.Kanda,M.Yamamoto,K.Kanno,et al.,Journal of Less-Common Metals,1991,172-174 ,1227.
  • 2[2]T.Sakai,A.Yuasa,H.Ishikawa,et al.,J.Less-Common Metal,1991,172-174,1194.
  • 3[3]S.Bruckenstein,R.R.Gadde,J.Am.Chem .Soc.,1971,93,793.
  • 4[4]G.Diehl,U.Karst,Anal.Bioanal.Chem.,2002,373,390.
  • 5[5]P.Novak,J.C.Panitz,F.Joho,et al.,J.Power Sources ,2000,90,52.
  • 6[6]M.Winter,R.Imhof,F.Joho,et al.,Journal of Power Sources,1999,81-82,818.
  • 7[7]R.Imhof,P.Novak,J.Electrochem.Soc.,1999,146,1702.
  • 8[8]M.Lanz,P.Novak,J.Power Sources,2001,102,277.