期刊文献+

Trace Determination of Zirconium(Ⅳ) by Anodic Adsorptive Voltammetry at a Carbon Paste Electrode 被引量:4

Trace Determination of Zirconium(Ⅳ) by Anodic Adsorptive Voltammetry at a Carbon Paste Electrode
下载PDF
导出
摘要 A new sensitive adsorptive voltammetric method was described for the determination of zirconium at a carbon paste electrode (CPE) in the presence of alizarin complexone (ALC). Optimal analytical conditions are: 1.0?0-6 or 5.0?0-7 mol/L ALC, 0. 20 mol/L HAC-NaAc (pH 4.3), accumulation for 60 s at 0 V (vs. SCE), and linear scanning from 0 V to 1.0 V at 250 mV/s. The peak potential of the complex is at 0.81 V. By using a model JP-303 polarographic analyzer, 2.0?0-10 mol/L (S/N=3) zirconium can be detected with a 90 s accumulation, when the 2nd-order derivative linear sweep technique is used, and the linear range is 6.0?0-10-2.0?0-8 mol/L (5.0?0-7 mol/L ALC) and 2.0?0-8-2.0?0-7 mol/L (1.0?0-6 mol/L ALC), respectively. The developed method was applied to the determination of trace zirconium in the ore samples with satisfactory results. A new sensitive adsorptive voltammetric method was described for the determination of zirconium at a carbon paste electrode (CPE) in the presence of alizarin complexone (ALC). Optimal analytical conditions are: 1.0?0-6 or 5.0?0-7 mol/L ALC, 0. 20 mol/L HAC-NaAc (pH 4.3), accumulation for 60 s at 0 V (vs. SCE), and linear scanning from 0 V to 1.0 V at 250 mV/s. The peak potential of the complex is at 0.81 V. By using a model JP-303 polarographic analyzer, 2.0?0-10 mol/L (S/N=3) zirconium can be detected with a 90 s accumulation, when the 2nd-order derivative linear sweep technique is used, and the linear range is 6.0?0-10-2.0?0-8 mol/L (5.0?0-7 mol/L ALC) and 2.0?0-8-2.0?0-7 mol/L (1.0?0-6 mol/L ALC), respectively. The developed method was applied to the determination of trace zirconium in the ore samples with satisfactory results.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第11期1315-1318,共4页 中国化学快报(英文版)
关键词 ZIRCONIUM alizarin complexone carbon paste electrode anodic adsorptive voltamme- try. Zirconium, alizarin complexone, carbon paste electrode, anodic adsorptive voltamme- try.
  • 相关文献

参考文献8

  • 1[1]V. F. Dorofeeva, S. L. Rogantinskaya, A. P. Zh. Kreshkow, Anal. Khim., 1979, 34, 913.
  • 2[2]J. N. Li, Y. F. Zhang and X. J. Zhao, Chem. J. of Chin. Univ., 1997, 18, 372.
  • 3[3]F. C. Meng, S. X. Li, P. H. Zhao, "Polarographic Complex Adsorptive Wave and Catalytical Wave". Publishing House of Wuhan University , Wuhan, 2001, p.203.
  • 4[4]J. Wang, T. Zh. Peng, K. Varughese, Talanta, 1987, 34(6), 561.
  • 5[5]I. Svancara, K. Vytras, J. Zima, J. Barek, Anal. Chem., 2001, 31, 311.
  • 6[6]J. N. Li, J. Zhang, P. H. Deng , J. J. Fei, Analyst, 2001, 126(11), 2032.
  • 7[7]J. N. Li, J. Zhang , P. H. Deng , Y. Q.Peng, Analytica Chimica Acta, 2001, 431(1), 81.
  • 8[8]J. N. Li, A. J. Lo, Natural Science Journal of Xiangtan University, 1983, 5, 64.

同被引文献31

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部