期刊文献+

Simultaneous determination of adenine, uridine and adenosine in cordyceps sinensis and its substitutes by LC/ESI-MS 被引量:6

Simultaneous determination of adenine, uridine and adenosine in cordyceps sinensis and its substitutes by LC/ESI-MS
下载PDF
导出
摘要 A simple, sensitive and reproducible high performance liquid chromatography-mass spectrometry coupled with electrospray ionization method for simultaneous separation and determination of adenine, adenosine and (uridine) was developed. The analytical column is a 2.0 mm×150 mm Shimadzu VP-ODS column and volume fraction of the mobile phase is (86.5%)water, 12.0%methanol and 1.5%formic acid. 2-chloroadenosine was used as internal standard. Selective ion monitoring mode and selective ion monitoring ions at ratio of mass to electric charge of 136 for adenine, 268 for adenosine and 267 for uridine were chosen for quantitative analysis of the three active components. The results show that the regression equations and linear range are Y=0.062X+(0.005) and 2.0140.0 (μg·mL-1)for adenine, Y=0.049X+0.004 and 4.0115.0 μg·mL-1 for uridine, (Y=0.154X)+0.014 and (1.0125.0) μg·mL-1 for adenosine. The limits of detection are 0.6 μg·mL-1 for adenine, 1.0 μg·mL-1for uridine and (0.2 μg·mL-1) for adenosine. The recoveries of the three constituents are from 96.6% to 103.2%. A simple, sensitive and reproducible high performance liquid chromatography-mass spectrometry coupled with electrospray ionization method for simultaneous separation and determination of adenine, adenosine and (uridine) was developed. The analytical column is a 2.0 mm×150 mm Shimadzu VP-ODS column and volume fraction of the mobile phase is (86.5%)water, 12.0%methanol and 1.5%formic acid. 2-chloroadenosine was used as internal standard. Selective ion monitoring mode and selective ion monitoring ions at ratio of mass to electric charge of 136 for adenine, 268 for adenosine and 267 for uridine were chosen for quantitative analysis of the three active components. The results show that the regression equations and linear range are Y=0.062X+(0.005) and 2.0140.0 (μg·mL^(-1))for adenine, Y=0.049X+0.004 and 4.0115.0 μg·mL^(-1) for uridine, (Y=0.154X)+0.014 and (1.0125.0) μg·mL^(-1) for adenosine. The limits of detection are 0.6 μg·mL^(-1) for adenine, 1.0 μg·mL^(-1)for uridine and (0.2 μg·mL^(-1)) for adenosine. The recoveries of the three constituents are from 96.6% to 103.2%.
出处 《Journal of Central South University of Technology》 2004年第3期295-299,共5页 中南工业大学学报(英文版)
基金 Project ( 2 0 175 0 3 6and 2 0 2 3 5 0 2 0 )supportedbytheNationalNaturalScienceFoundationofChina
关键词 腺嘌呤 质谱分析 静电 电离 虫草素 核苷 high performance liquid chromatography electrospray ionization interface mass spectrometry cordyceps sinensis nucleoside
  • 相关文献

参考文献5

二级参考文献29

共引文献267

同被引文献120

引证文献6

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部