铁氰化钾-过氧化氢氧化鲁米诺发光的研究及应用 被引量:2

The Chemiluminescence of Luminol Reacted with Potassium Ferricyanide-Hydrogen Peroxide and Its Application
下载PDF
导出
摘要 研究了铁氰化钾-过氧化氢氧化鲁米诺化学发光行为,依据铜对该化学发光反应的抑制作用,建立了微量钢的化学发光测定法,该法要出限为2.5×10^(-10)g/ml,线性范围为1.0×10^(-9)~1.0×10^(-5)mg/L.此方法已成功地用于实际水样中微量铜的测定. The Chemiluminescent reaction of luminol with potassium ferricyanide in the presence of hydrogen per- oxide has been examined. The kinetic process agreed with the index attenuation formula I(t)=45exp[-0.053 (t-t_(max))](t≥t_(max))and the constant of attenuation speed was 0.053 sec^(-1). Based on the chemiluminescent re- action, a new method for the determination of trace copper has been developed by the inhibition of copper. The determination limit for Cu (Ⅱ) is 2.5×10^(-10)g/ml and the linear range is from 1.0×10^(-9)g/ml to 1.0×10^(-5)g/ml. The method has been applied to detect trace copper in water sample.
出处 《科技通报》 1993年第6期392-396,共5页 Bulletin of Science and Technology
基金 国家自然科学基金
关键词 化学发光 铁氰化钾 过氧化氢 luminol chemiluminescence copper
  • 相关文献

同被引文献20

  • 1朱昌青,王伦,吴家良.鲁米诺-亮绿SF-过氧化氢-铜(Ⅱ)化学发光体系的研究[J].分析试验室,1996,15(4):71-72. 被引量:7
  • 2武汉大学.无机化学(第二版)[M].北京:高等教育出版社,1983..
  • 3Tanaka M,Kamiya S,Shibue A ,et al. Electrochemical luminescence based homogenous i mmunosensor[J]. Sensors & Actuators,B Chemicals, 1993,13 (1-3) : 184-187.
  • 4Sheng C ,Yang O,Wang C M. Clay enhanced electrochemiluminescenee and its application in the detection of glucose[J]. J Electrochem Soc, 1998,145 ( 8 ) : 2654-2659.
  • 5Knight A W, Greenway G M. Occurrence,mechanisms and analytical applications of electrogenerated chemiluminescence[J]. Analyst, 1994,119: 879-89O.
  • 6Rubinstein I, Martin C R, Bard A J. Electrogenerated chemiluminescent determination of oxalate[J]. Anal Chem, 1983,55(5 ) : 1580-1583.
  • 7Greenway G M,Knight A W,Knight P J. Electrogenerated chemiluminescent determination of codeine and related alkaloids and pharmaceuticals with tris (2,2'-bipyridine)ruthenium(II)[J]. Analyst, 1995,120(I0) :2549-2552.
  • 8Knight A W, Greenway G M. Relationship between structural attributes and observed electrogenerated chemiluminescence (ECL) activity of tertiary amines as potential analytes for the tris(2,2-bipyridine)ruthenium(II) ECL reaction[J]. Analyst,1996,121 : 101R-106R.
  • 9Hong Hsiu-Chen ,Huang Hsuan-Jung. Flow injection analysis of uric acid with a uricase- and horseradish peroxidase-coupled Sepharose column based luminol chemiluminescence system[J]. Anal Chim Acta, 2003,499(1-2) :41-46.
  • 10Kannan P,John S A. Determination of nanomolar uric and ascorbic acids using enlarged gold nanoparticles modified electrode[J]. Anal Biochem, 2009,386 ( 1 ) : 65 -72.

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部