期刊文献+

高效液相色谱法测定芬苯达唑原料中的有关物质 被引量:1

Determination of the related substances in fenbendazole by HPLC
下载PDF
导出
摘要  用高效液相色谱法测定芬苯达唑原料中可能存在的2种杂质的含量。采用InertsilODS 3色谱柱(4.6mm×250mm,5μm),以甲醇 水 冰醋酸(30∶70∶1,V/V)为流动相A和甲醇 水 冰醋酸(70∶30∶1,V/V)为流动相B梯度洗脱,检测波长280nm,流速1.0mL/min,进样量10μL。用归一化法计算原料中杂质的含量,与外标法结果比较无显著性差异。 A method for determining of the related substances in fenbendazole by HPLC with a linear gradient elution was established. An Inertsil ODS-3 column(4.6 mm×250 mm, 5 μm) was used with the mobile phase A of methanol-water-acetic acid(30∶70∶1,V/V) and B of methanol-water-acetic acid(70∶30∶1,V/V) which were mixed by linear gradient.The detection wavelength was 280 nm.
作者 冯克清
出处 《中国兽药杂志》 2004年第11期19-21,共3页 Chinese Journal of Veterinary Drug
关键词 高效液相色谱法 含量测定 芬苯达唑 原料 抗蠕虫药 fenbendazole related substance HPLC
  • 相关文献

参考文献2

  • 1中国兽药典委员会.中华人民共和国兽药典一部二○○○年版[S].北京:化学工业出版社,.附录41-42.
  • 2British Pharmacopoeia Commission.British Pharmacopoeia(Veterinary)[S].2003.57.

共引文献4

同被引文献23

  • 1肖小华,刘淑娟,刘霞,蒋生祥.离子液体及其在分离分析中的应用进展[J].分析化学,2005,33(4):569-574. 被引量:60
  • 2孙伟,高瑞芳,毕瑞锋,焦奎.室温离子液体六氟磷酸正丁基吡啶修饰碳糊电极的制备与表征[J].分析化学,2007,35(4):567-570. 被引量:28
  • 3Qi-Wen Duan, Yang-Feng Liu, Rockwell S, Fenbendazole as a potential anticancer drug[ J]. Anticancer Res,2013,33 (2) :355-362.
  • 4Lehr K H, Datum P. Simultaneous determination of fenben- dazole and its two metabolites and two triclabendazole me- tabolites in plasma by high-performance liquid chromatog- raphy[ J]. J Chromatogr B, 1986,382:355-360.
  • 5Gomes A R, Nagaraju V, Gomes A R, et al. High-perform- ance liquid chromatographic separation and determinationof the process related impurities of mebendazole, fenben- dazole and albendazole in bulk drugs[ J]. J Pharm Biomed Anal,2001,26(5-6) :919-927.
  • 6Rummel N, Chung I, Shaikh B. Determination of alben- dazole,? fenbendazole, and their metabolites in mouse plasma by high performance liquid chromatography using fluorescence and ultraviolet? detection[ J ]. J Liq Chroma- togr Relat Technol, 2011,34 ( 18 ) :2211-2223.
  • 7Zrrfii6M, Gros M, BabicS, et al, Analysis of anthelmintics in surface water by ultra high performance liquid chroma- tography coupled to quadrupole linear ion trap tandemmass spectrometry E J ]- Chernosphere, 2014,99 ( 3 ) : 224- 232.
  • 8de Oliveira M F,Stradiotto N R. Voltammetric determina- tion of fenbendazole in veterinarian formulations [ J ]. J Pharrn Biomed Ana/,2002,30(2) :279-284.
  • 9Msagati T A M, Ngila J C, Voltammetric determination of a benzimidazole anthelmintic mixture at a poly (3-methyl- thiophene)-modified glassy carbon electrode[ J ]. S Aft" J Chern ,2003 , 56 : 5 -9.
  • 10de Prada G V,Loaiza 0 A,Serra B,et al. Molecularly im- printed polymer solid-phase extraction coupled to square wave voltammetry at carbon fibre microelectrodes for the determination of fenbendazole in beef liver[ J ]. Anal Bion- al Chera,2007,388( 1 ) :227-234.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部