期刊文献+

Differential Pulse Anodic Stripping Voltammetric Determination of Lead with Heparin Modified Electrode

Differential Pulse Anodic Stripping Voltammetric Determination of Lead with Heparin Modified Electrode
原文传递
导出
摘要 A novel differential pulse anodic stripping voltammetry for the determination of trace amounts of lead, using a biomacromolecule heparin drop-coated modified glassy carbon electrode, has been described. Pb2+ was deposited on the surface of a heparin-modified electrode at -1.0 V (vs. SCE) via forming Pb2+-heparin and subsequent re-duction at the electrode. In the following step, Pb-heparin was oxidized, and voltammograms were recorded by scanning the potential in a positive direction. Conditions were optimized with respect to the pH of the medium, the mass of drop-coated heparin, accumulation potential and accumulation time. The peak current was proportional to the Pb2+ concentration in the range of 2.0×10-9 to 7.0×10-7 mol/L. The detection limit was 3.0×10-10 mol/L. The relative standard deviation was 4.83% for 1.0×10-8 mol / L Pb2+ (n=10). The developed method has been applied to the determination of Pb2+ in water samples with satisfactory results. A novel differential pulse anodic stripping voltammetry for the determination of trace amounts of lead, using a biomacromolecule heparin drop-coated modified glassy carbon electrode, has been described. Pb2+ was deposited on the surface of a heparin-modified electrode at -1.0 V (vs. SCE) via forming Pb2+-heparin and subsequent re-duction at the electrode. In the following step, Pb-heparin was oxidized, and voltammograms were recorded by scanning the potential in a positive direction. Conditions were optimized with respect to the pH of the medium, the mass of drop-coated heparin, accumulation potential and accumulation time. The peak current was proportional to the Pb2+ concentration in the range of 2.0×10-9 to 7.0×10-7 mol/L. The detection limit was 3.0×10-10 mol/L. The relative standard deviation was 4.83% for 1.0×10-8 mol / L Pb2+ (n=10). The developed method has been applied to the determination of Pb2+ in water samples with satisfactory results.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2004年第6期553-557,共5页 中国化学(英文版)
基金 Project supported by the National Natural Science Foundation of China (No. 20377007).
关键词 HEPARIN chemically modified electrode LEAD differential pulse anodic stripping heparin, chemically modified electrode, lead, differential pulse anodic stripping
  • 相关文献

参考文献2

共引文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部