分析了全静叶可调轴流风机的静叶可调系统失灵原因,论述了机组连续运转条件下,处理全静叶可调系统故障的可能性及处理方法,提出了静叶可调系统维护保养及使用注意事项。
The failure reason of stationary blade adjustable system for whole stationary blade adjustable axial flow blower is analized.The posibility for treating the failure of whole stationary blade adjustable system,and the handling method under the condition of machine set at contineous operation,are mentioned.The matters needing attention for maintenace and application of stationary blade adjustable system are put forward.