期刊文献+

储罐底板漏磁检测传感器设计 被引量:8

DEVELOPMENT OF THE TRANSDUCER FOR TANK FLOOR INSPECTION BASED ON MAGNETIC FLUX LEAKAGE TESTING
下载PDF
导出
摘要 漏磁检测是储罐底板表面腐蚀检测的重要方法。传统的检测传感器主要根据试验结果设计。利用有限元软件ANSYS研究了传感器励磁装置的参数对钢板局部磁化的影响,设计了漏磁信号的后续处理及数据采集电路,研制了相应的漏磁检测传感器。试验证明,该传感器具有较高的检测灵敏度。 Magnetic flux leakage (MFL) testing is one of the most important methods for tank floor inspection. Traditional transducers were often designed by experiments. Finite element software ANSYS was used to optimize the parameters of the magnetizing system. The circuits for detecting, post-processing and data acquisition were designed, and a transducer were developed. Experiments showed that the transducer had good sensitivity.
出处 《无损检测》 2004年第12期612-615,共4页 Nondestructive Testing
关键词 漏磁检测 局部磁化 传感器 励磁装置 容器 Magnetic flux leakage testing Local magnetization Transducer Magnetizing system Tank
  • 相关文献

参考文献1

  • 1Jansen HJM, Camp PBJ van de, Geerdink M. Mag-netization as a key parameter of magnetic flux leakagepigs for pipeline inspection[J]. INSIGHT, 1994, 36(9) :672-677.