摘要 以我国第一条±500 kV葛州坝至上海超高压直流输电线路为模型,运用电磁暂态计算程序EMTP.对开断直流线路过程中高压直流断路器的工作条件进行了计算,分析了系统参数对断路器工作条件的影响,确定出在最严重情况下,即I=4kA时葛-上线开断过程中吸能装置耗散能量达15.7MJ,通流时间为11.6ms。同时计算分析了金属回线转移开关MRTB开断过程中直流断路器的工作条件,并与线路用宜流断路器一断口的情况进行比较,提出了首先发展MRTB的研究方向。 In this paper, the analysis and calculation of operating conditions of HVDCCB and metallic return transfer breaker (MRTB) during interrupting process in Gezhouba-Shanghai HVDC transmission line have been made with the Electro-Magnetic Transients Program (EMTP). The influence on energy absorber which is made by the system inductance and interrupting current is analysed. In the most serious situation, when I = 4kA, the dissipated energy in energy absorber is 15.1 MJ, and the current duration is 11.6 ms. At the same time, the comparison of operating conditions between HVDCCB and MRTB is made.
作者 沈力 吉嘉琴
出处 《清华大学学报(自然科学版)》 EI CAS CSCD 北大核心 1993年第4期13-21,共9页 Journal of Tsinghua University(Science and Technology)
关键词 高压 直流断路器 输电线路 断路器 high voltage DC circuit breaker MRTB energy absorber
  • 相关文献

参考文献2

二级参考文献2

  • 1张力超,高压电器,1991年,2期
  • 2张力超,1990年

共引文献7

同被引文献30

  • 1苏宇红,刘朴,张海峰.交流高压断路器三相合成试验燃弧时间的确定及整定方法简介[J].高压电器,2006,42(4):313-314. 被引量:7
  • 2赵怀军,马鹏,傅卫平,程远贵.基于DSP的断路器机械特性检测装置[J].高压电器,2006,42(5):382-384. 被引量:7
  • 3郑占锋,邹积岩,董恩源,段雄英.直流开断与直流断路器[J].高压电器,2006,42(6):445-449. 被引量:101
  • 4鲍敏锋.高压直流断路器的研制[J].高压电器,1990,26(1):26-34. 被引量:14
  • 5GREEN S. HVDC systems gotland: the HVDC pioneer[ J ] Power Engineering International, 2004, 12(7) : 28 -29.
  • 6MORISH1TA Y, ISHIKAWA T, YAMAGUCHI. Applications of DC breakers and concepts for superconducting fault-current limiter for a DC distribution network [J]. IEEE Transactions on Applied Superconductivity, 2009, 19 (4) : 3658 - 3664.
  • 7WANG J, N/NG T. A new method of automatic monitoring DC breaker by using GPRS technique [ C]// Springer-Vedag Berlin Heidelberg: 2011 : 113 - 120.
  • 8NEGARI S, XU D. A new solid-state HVDC circuit breaker to- pology for offshore wind farms C l// 1EEE 5th International Symposium on Power Electronics for Distributed Generation Sys- tems (PEDG), 2014:1 -5.
  • 9BACHMANN B, MAUTHE G, RUOSS E, et al. Development of a 500 kV airblast HVDC circuit breaker [ J ]. IEEE Transac- tions on Power Apparatus and Systems, 1985, 104(9) : 2460 - 2466.
  • 10FRANCK C M. HVDC circuit breakers : a review identifying fu- ture research needs [ J]. IEEE Transactions on Power Delivery, 2011, 26(2) : 998 -1007.

引证文献3

二级引证文献160

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部