在公称3 t电弧炉上进行了水冷复合电极试验,电极消耗由5.82 kg/t降低至4.98 kg/t,节约14.43%。可用性、经济性、安全性得到了证实。为满足高生产率和现代电弧炉的需要,绝缘和控制尚须进一步改进。
The water-cooled cmplex electrode experiment has been completed in a 3 t electric arc furnace, The consume of electrode decreases from 5.82 kg/t to 4.98 kg/t, i.e. 14.43% electrode saving. The fusibility, safety and economy are proved. But, its insulation and control should be improved furthermore to meet the needs of high productivity and modernization of the electric arc furnaces.
出处
《钢铁》
CAS
CSCD
北大核心
1993年第4期17-20,共4页