摘要
在pH=5 4的六次甲基四胺-盐酸缓冲溶液、100℃恒温水浴中,Ni2+能催化双氧水氧化胭脂红褪色,据此提出采用胭脂红褪色光度法测定锌镍合金镀液中的镍含量。确定了适宜的试验条件,其中测定波长为518nm。讨论了该镍催化反应的表观活化能以及杂质离子对测定结果的影响,并给出了某电镀厂碱性锌镍合金镀液中镍含量的测定结果。该方法简便,准确度高,能满足生产中快速测定的要求。
In the buffer solution of hexamethyle netetramine-hydrochloric acid of pH=5.4 with water bath of (100 ℃,) carmine red can be oxidized to fade by hydrogen peroxide, in which Ni^(2+) is used as catalyst, and thereby carmine red fading spetrophotometry was promoted to measure the Ni^(2+) content in Zn-Ni alloy electroplating solution. The relevant experimental conditions were obtained and the suitable wavelength was 518 nm. The influences of the apparent activation energy of Ni^(2+) catalytic reaction and the impurity ions in the solution on the testing results were discussed. The Ni^(2+) content in the alkaline Zn-Ni alloy electroplating solution of one electroplating factory was tested. The results show that this method is easy and highly accurate, and can meet the demand of fast measurement in production.
出处
《电镀与涂饰》
CAS
CSCD
2004年第6期25-27,共3页
Electroplating & Finishing
基金
烟台师范学院校继续教育研究基金资助项目(414-610015)。
关键词
光度法
胭脂红褪色
Zn-Ni合金镀液
镍含量
spectrophotometry
carmine red fading
Zn-Ni alloy electroplating solution
Ni^(2+) content