摘要
现行的铁路客车空调系统设计及其维护中存在一些影响IAQ的因素。本文从室内设计参数、新风采集、通风系统、通风方式及气流组织、增氧等几个方面研究了青藏铁路空调客车IAQ,并提出了在空调系统设计维护时应注意的问题。
The factors that infecting the IAQ of Qinghai-Tibet passenger train HVAC System are discussed in this paper, such as outdoor air intake flow, indoor parameter selection, air ventilation system design, fresh air regulation and so on. Some methods are offered for improving the IAQ of Qinghai-Tibet passenger HVAC train.
出处
《制冷与空调(四川)》
2004年第4期68-71,78,共5页
Refrigeration and Air Conditioning
关键词
青藏铁路
空调系统
IAQ
通风方式
增氧
Qinghai-Tibet rail
HVAC System
IAQ
Ventilation system
Feeding oxygen system