摘要 对冷面上水珠的冻结过程及其影响因素进行了实验研究。实验结果表明:水珠温度被降到℃以下时,水珠并未马上冻结,而是呈过冷态并持续一段时间,在某一时刻开始冻结时过冷水珠温度回升,整个水珠完全冻结后,冰珠温度又开始下降至与环境平衡的温度。冷面温度是影响水珠冻结的主要因素,表面接触角、粗糙度以及水珠体积等对水珠冻结也有影响。 The freezing process of super-cooled drops on cold surfaces and its affecting factors were experimentally investigated. The experimental results showed that when the drop temperature was reduced to a value below 0°C, the drop did not freeze immediately but kept in the super-cooled state for a while. Thereafter the super-cooled drop began to freeze, accompanied by an increase in the drop temperature. The drop temperature turned to decrease until reaching a value equalized with the ambient when the drop was completely frozen. It was found that the cold surface temperature was a primary factor affecting the super-cooled drop freezing, while the surface contact angle and roughness and the drop volume also have some effects on the super-cooled drop freezing.
出处 《工程热物理学报》 EI CAS CSCD 北大核心 2005年第1期104-106,共3页 Journal of Engineering Thermophysics
基金 国家自然科学基金项目资助(No.50476011)
关键词 过冷水珠 冻结 冻结开始时间 super-cooled drop freezing freezing onset time
  • 相关文献

参考文献5

  • 1吴晓敏,王维城.冷面结霜初始形态的理论分析[J].工程热物理学报,2003,24(2):286-288. 被引量:35
  • 2吴晓敏,单小丰,王维城,唐黎明.冷表面结霜的微细观可视化研究[J].清华大学学报(自然科学版),2003,43(10):1437-1440. 被引量:29
  • 3Hobbs P V, Ice Physics. Oxford: Clarendon Press Oxford, 1974.
  • 4Strub M, Jabbour O, Strub F. Experimental Study and Modeling of the Crystallization of a Water Droplet. International Journal of Refrigeration, 2003, 26(1): 59-68.
  • 5Hindmarsh J P, Russell AB, Chen XD. Experimental and Numerical Analysis of the Temperature Transition of a Suspended Freezing Water Droplet. Int. J. Heat and Mass Transfer, 2003, 46(7): 1199-1213.

二级参考文献7

  • 1Kinsara A, Elsayed M, AL-Rabghi O. Proposed energy-efficient air-conditioning system using liquid desiccant[J]. Applied Thermal Engineering J, 1996, 16:791-806.
  • 2Kinsara A, AL-Rabghi O, Elsayed M. Parametrical study of an energy efficient air conditioning system using liquid desiccant [J]. Applied Thermal Engineering J, 1997, 18:327 - 335.
  • 3Ma H B, Peterson G P. Thermodynamic analysis of the influence of electric fields on frost formation [J]. J Thermophysics, 1995, 9(3): 562-564.
  • 4Okoroafor E U, Nweborough M. Minimizing frost growth on cold surfaces exposed to humid air by means of crosslinked hydrophilic polymeric coatings [J]. Applied Thermal Engineering J, 2000, 205 737 - 758.
  • 5Wu Xiaomin, Webb R L. Investigation of the possibility of frost release from a cold surface [J]. Experimental Thermal and Fluid Science, 2001, 24 (3 - 4) : 151 - 156.
  • 6Adamson A W, Gast A P. Physical Chemistry of Surface[M]. New York: John Wiley & Sons, Inc, 1997.
  • 7吴晓敏,王维城.冷面结霜初始形态的理论分析[J].工程热物理学报,2003,24(2):286-288. 被引量:35

共引文献51

同被引文献50

引证文献15

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部