通过对GW5型闸刀各部位发热原因分析,阐明各发热部位的检修质量及标准,对提高GW5型闸刀的检修质量,确保GW5型闸刀安全运行可靠供电,提出解决方法。
This article analyzes heating causes of parts of the GW5 type switch and puts forward the reconditioning quality criteria of the switch parts to ensure safety running and reliable power supply.
出处
《安徽电力》
2004年第4期53-55,共3页
Anhui Electric Power