摘要 电厂中凝汽器循环冷却水消耗占电厂用水量很大一部分 ,采用循环水加酸调整水质的方法 ,在增大循环冷却水浓缩倍率的同时 ,控制好加酸后的循环水的 pH值 ,可以有效地防止凝汽器铜管结垢 ,以及铜管的腐蚀 ,最主要的是可以有效地减少电厂新鲜水的用量。此外 ,由于减少了循环水的外排 ,为防止凝汽器结垢而投加的阻垢剂的用量也相应减少 ,收到了较好的经济效益。 In Power-plant,the consumption of cooling water is the major part of all flesh water. Adopting the new method—adding-acid to circle cooling water, a great part of flesh water can be saved. The concentration proportion being increased,the PH value of water being well controlled to prevent the copper tube staining and scaling. At the same time, the consumption of anti-scale chemical reagent decreased too. It proved that this new method can bring tremendous economic benefit.
出处 《电站辅机》 2004年第4期15-18,21,共5页 Power Station Auxiliary Equipment
关键词 水质调整 加酸 浓缩倍率 阻垢 新鲜水补水 water quality adjustment add acid concentration-proportion anti-scale supplement of flesh water
  • 相关文献

参考文献2

二级参考文献7

  • 1杨武.金属的局部腐蚀[M].北京:化学工业出版社,1993.316.
  • 2化工设计全书编辑委员会.换热器设计[J].上海:上海科学技术出版社,1984.
  • 3张万峰译.凝汽器和其它热交换器管的VGB准则[J].电力设计水处理技术,1991,(2).
  • 4GEMoller.Seminarproceedings:PreventionofCondensersFailures—theStateoftheArt[R].EPRI-CS-4329-SR.Dec.1985.section7.
  • 5BechtelNationalInc.Steam-plantSurface-condenserLeakage—studyUpdate[R].EPRI-NP-2062,Finalreport,May1982.
  • 6梁磊,吴一平,周国定.电厂凝汽器冷却管腐蚀及泄漏情况的调查[J].电站辅机,1998(3):6-10. 被引量:5
  • 7梁磊,周国定,解群,姚秀平,吴一平.不锈钢管在我国凝汽器上的应用前景[J].中国电力,1998,31(11):37-41. 被引量:26