摘要
分析了氧枪坠落事故的根本原因。经周密计算 ,自行设计了氧枪自锁装置。该装置投资少 ,安全性高 ,已成功防止氧枪坠炉事故的发生。
The basic reasons leading to oxygen lance falling are analyzed. The self-lock installation of oxygen lance is designed on the basis of careful calculation. Owing to low investment and high security, the installation has successfully prevented oxygen lance from falling.
出处
《鞍钢技术》
CAS
2004年第6期50-52,共3页
Angang Technology
关键词
氧枪
转炉
改造
装置
防止
事故
converter oxygen lance self-lock installation