摘要
对热泵干衣机进行振动噪声源识别的基础上,用 ANSYS 对热泵机组及其配管系统进行模态和谐响应分析,提出冷凝管道的最佳形状,并且讨论了加装避振管的隔振效果和工程上的可行性.
Based on identifying the noise sources of heat pump dryer, the paper analyzes the device and its piping system’s harmonic response and modal by ANSYS. The best shape of condenser pipe is given. What is more, the effect of anti-vibration pipe and its feasibility are also discussed.
出处
《机电设备》
2004年第6期12-16,共5页
Mechanical and Electrical Equipment
基金
江苏科技大学自制设备项目