期刊文献+

钢筋混凝土阴极保护的试验研究 被引量:1

EXPERIMENTAL INVESTIGATION OF THE CATHODIC PROTECTION IN REINFORCED CONCRETE
下载PDF
导出
摘要 本文从混凝土中钢筋的阴极极化、去极化特征以及在氯盐环境中阴极保护对钢筋混凝土握裹力和界面水化产物的影响等方面对钢筋混凝土的阴极保护进行了试验研究。研究查明:阴极保护不影响钢筋与混凝土的握裹力,对水泥的水化无不良影响;同时证实了混凝土保护层质量和系统扩散电阻也是影响钢筋混凝土阴极保护的主要因素之一。 In this paper, we have studied the cathodic polarization and the depolarization character of the steel in concrete, influence of cathodic protection in the chloridc environment on the grip of reinforced concrete and hydrated compound on the interface of the steel and concrete. The result shows that the cathodic protection has no influence over the grip and is not bad for hydrated compound of cement. It also confirms that the concrete cover quality and the system diffuse resister have influence over the cathodic protection of reinforced concrete.
出处 《上海建材学院学报》 CSCD 1993年第2期153-160,共8页
关键词 钢筋混凝土 阴极保护 试验 reinforced concrete cathodic protection
  • 相关文献

同被引文献6

  • 1高军义.PCCP管系钢筋阴极保护在取水改造工程中的应用[J].西北水电,2007(1):48-50. 被引量:3
  • 2英国标准局.阴极保护实施规范[M].洪定海,译.北京:国防工业出版社,1985.
  • 3周正,马酉生.预应力输水管线阴极保护通过部级鉴定[J].混凝土与水泥制品,1984(6):64.
  • 4Veazey M V. CP retrofitting underway on Libyan project [J]. MP, 2005(4):22-23.
  • 5中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.GB/T28725--2012《埋地预应力钢筒混凝土管道的阴极保护》[S].北京:中国标准出版社,2012.
  • 6胡士信,王东黎,张本革,窦宏强,陈弘,钱德琳.预应力钢筒混凝土管阴极保护技术应用介绍[J].南水北调与水利科技,2008,6(1):303-307. 被引量:15